{"product_id":"ci526-3bse006085r1-abb-advant-ocs-af100-communication-interface","title":"CI526 3BSE006085R1 | ABB | Advant OCS AF100 Communication Interface","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB CI526 (3BSE006085R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-speed communication interface for the Advant Fieldbus 100 (AF100) network. This module provides the essential data link between Advant OCS controllers and distributed S800 I\/O clusters. By utilizing deterministic broadcast technology, the CI526 ensures that time-critical process data and safety interlocks reach the control logic without network jitter or packet collisions. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your legacy or modern Advant system maintains peak communication integrity.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe CI526 utilizes specialized AF100 bus logic to manage real-time data throughput:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArticle Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3BSE006085R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Interface (CI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvant Fieldbus 100 (AF100)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvant Controller 400 series, S800 I\/O systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTyp. 120 mA at 24 V d.c.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed deterministic bus communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull galvanic isolation between bus and internal logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSweden\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Control Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CI526 implements the AF100 protocol to guarantee fixed scan times for all connected I\/O. This ensures that critical PID loops and safety shutdowns execute at precise, repeatable intervals regardless of total network traffic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in galvanic isolation protects the internal electronics from ground loops and electrical noise common in heavy industrial environments. This prevents signal corruption when routing cables near high-power switchgear or variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Networking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports redundant AF100 bus configurations. When paired with a second CI526 or redundant cabling, the system maintains uninterrupted communication even if a physical cable break occurs on one segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Level Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated front-panel LEDs provide immediate visual feedback on \"Run,\" \"Fault,\" and \"Traffic\" status. This allows maintenance teams to verify bus health at a glance without needing to connect a laptop or engineering station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSweden-Engineered Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManufactured to ABB’s stringent Swedish quality standards, the CI526 handles the thermal stress of enclosed control cabinets, offering a high MTBF (Mean Time Between Failures) for 24\/7 continuous process operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CI526 replace the older CI522 or CI520 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CI526 often serves as a modern, more robust alternative within the AF100 family. However, you must verify your specific Advant Controller (AC410\/AC450) software version to ensure driver compatibility before swapping hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific Module Termination Unit (MTU)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the CI526 must seat into a compatible baseplate or MTU to access the AF100 bus and 24V power. Ensure the pins are correctly aligned before securing the module to prevent mechanical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the AF100 station address on the CI526?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module typically uses hardware address switches located on the side or rear of the unit. You must set a unique address for each station on the network before powering up the cluster to avoid communication conflicts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with S800 High Integrity (HI) systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the CI526 facilitates AF100 communication, specific SIL-rated applications may require \"HI\" designated interface variants. Always consult your safety lifecycle documentation for mandatory safety-system hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52506647462197,"sku":"CI526 3BSE006085R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CI526.png?v=1774850734","url":"https:\/\/www.5gplc.com\/products\/ci526-3bse006085r1-abb-advant-ocs-af100-communication-interface","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}