{"product_id":"ci511-ethcat-1sap220900r0001-abb-ac500-distributed-automation-i-o-module","title":"CI511-ETHCAT 1SAP220900R0001 | ABB | AC500 Distributed Automation I\/O Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB CI511-ETHCAT (1SAP220900R0001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance EtherCAT slave interface within the S500 distributed automation ecosystem. This hybrid module integrates a versatile array of signal types—including 4 analog inputs (Voltage, Current, RTD), 2 analog outputs, 8 digital inputs, and 8 digital outputs—into a single compact unit. It manages decentralized data exchange with millisecond precision and features integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCam switch functionality\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor time-critical switching tasks. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your industrial network benefits from uncompromised factory-certified hardware.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe CI511-ETHCAT provides comprehensive signal density for complex automation architectures:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEtherCAT Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Interfaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 x Industrial Ethernet (RJ45)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Channels (Supports Voltage, Current, and RTD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Channels (Supports Voltage and Current)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Channels (24V DC, 5mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Channels (Transistor, 24V DC, 0.5A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Delay Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjustable from 0.1 ms to 32 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (Range: 20.4 to 28.8 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e67.5 mm (W) x 76 mm (H) x 62 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.138 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAll-in-One Hybrid Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CI511-ETHCAT combines analog and digital I\/O on a single module. This eliminates the need for separate communication couplers and multiple I\/O cards, significantly reducing hardware costs and the physical footprint on the DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Cam Switch Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module processes high-speed switching tasks locally. This hardware-based control allows for precise output triggering based on time or position data, bypassing communication latencies typically associated with central PLC processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Analog Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 4 analog inputs supports U (Voltage), I (Current), and RTD (Resistance Temperature Detector) signals. This versatility allows engineers to interface with diverse field instruments—from pressure transmitters to PT100 sensors—without changing hardware modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDaisy-Chain Network Topology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual Industrial Ethernet ports allow for efficient daisy-chaining of S500 clusters. This reduces cabling complexity and ensures a clean, organized network layout within large-scale distributed automation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Low Latency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith an adjustable input delay starting at 0.1 ms, the CI511-ETHCAT captures rapid process fluctuations. This responsiveness supports high-speed machine control and synchronized motion applications where every millisecond affects throughput.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CI511-ETHCAT require a separate Terminal Base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must mount the CI511-ETHCAT onto a compatible S500 Terminal Base (such as the TU5xx series). The terminal base provides the necessary mechanical mounting and the electrical interface for the field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the analog inputs handle temperature sensors directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The inputs support RTD signals directly. This allows you to connect temperature sensors without needing an external signal converter or a specialized temperature module, simplifying your BOM (Bill of Materials).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum current capacity for the digital outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach of the 8 transistor outputs delivers up to 0.5A at 24V DC. These outputs include built-in protection to prevent damage during overload or short-circuit conditions at the field level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the module within an EtherCAT network?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou integrate the CI511-ETHCAT using an ESI (EtherCAT Slave Information) file. Once imported into your engineering tool (like Automation Builder), the module provides full access to its internal diagnostics and I\/O mapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52507114963253,"sku":"CI511-ETHCAT 1SAP220900R0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CI502-PNIO1SAP220700R00011_0a7c1498-453e-4013-8c47-720a5baa8743.jpg?v=1774854638","url":"https:\/\/www.5gplc.com\/products\/ci511-ethcat-1sap220900r0001-abb-ac500-distributed-automation-i-o-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}