{"product_id":"centum-vp-yokogawa-sec402-51-esb-bus-coupler-module","title":"CENTUM VP | Yokogawa | SEC402-51 ESB Bus Coupler Module","description":"\u003ch2\u003e\u003cspan class=\"qwen-markdown-text\"\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe Yokogawa SEC402-51 serves as the high-performance dual-port ESB (Enhanced Serial Bus) master interface, engineered to bridge Field Control Units (FCU) with distributed Node Units in the CENTUM VP architecture. It resolves complex cabling constraints in large-scale control cabinets by supporting a unique split-bus topology, allowing up to 9 I\/O units on the upper bus and 9 on the lower bus simultaneously. With a dedicated 128 Mbps transmission speed, this module ensures deterministic, low-latency data exchange critical for fast-loop process control in power generation and petrochemical refining. Its robust design supports both standard and hazardous location variants, providing flexible deployment options while maintaining the rigorous reliability standards expected of Yokogawa DCS infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"qwen-markdown-table\"\u003e\n\u003cthead class=\"qwen-markdown-table-thead\"\u003e\n\u003ctr class=\"qwen-markdown-table-thead-tr firstRow\"\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eParameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"qwen-markdown-table-tbody\"\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eESB Bus Coupler Module (Dual-Port Master)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eBrand \/ Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eYokogawa \/ CENTUM VP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eModel Number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eSEC402-51 (Variant of SEC402-5 Series)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePrimary Function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eESB Bus Master Interface for FCU-to-Node communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePort Configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e2-Port (Upper Bus \u0026amp; Lower Bus independent channels)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eConnectable Units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eMax 9 units per port (Total 18 units per module)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eTransmission Speed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e128 Mbps (High-speed I\/O data transfer)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eMax Transmission Distance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e10 meters per segment (Upper \u0026amp; Lower independent)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCurrent Consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e0.5 A @ 24 VDC (Typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eApprox. 0.24 kg (0.53 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCertification Options\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eStandard, Explosion Protected, ISA G3 Compliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eMounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eDIN Rail or CENTUM VP Node Slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eApplication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eHigh-density I\/O expansion, Redundant Bus Topologies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eModel Code Decomposition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe Yokogawa SEC402 series utilizes a specific suffix logic to define port count, safety ratings, and environmental compliance. Understanding these codes is essential for selecting the correct module for hazardous vs. non-hazardous areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePart Number Structure: SEC402-5XX\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSEC\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Series identifier for CENTUM VP ESB Communication Modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e402\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Functional code denoting the ESB Bus Coupler (Master) with dual-port capability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e5\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Base hardware revision indicating the 2-Port architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSuffix Codes (The last characters define the variant):\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e-E (e.g., SEC402-5E)\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eStandard Type\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e. No explosion protection. Suitable for general industrial control rooms and non-hazardous areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e-1 (e.g., SEC402-51)\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eExplosion Protected Type\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e. Designed for installation in hazardous locations where flammable gases or dust may be present. Meets specific intrinsic safety or flameproof standards required for oil \u0026amp; gas zones.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e-G3 (e.g., SEC402-5G3)\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eISA G3 Compliance\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e. Indicates the module meets the ISA-71.04 Grade G3 standard for corrosive environments (severe chemical exposure), often used in wastewater treatment or chemical processing plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003eNote\u003c\/em\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: The model \"SEC402-51\" specifically refers to the \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eExplosion Protected\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e variant of the dual-port coupler. Always verify the full suffix against your facility's area classification drawings before procurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eInstallation Recommendations and Wiring Guidelines\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eProper installation of the SEC402-51 is critical to leveraging its dual-bus capability. Mount the module securely in the Field Control Station slot or on the DIN rail adjacent to the FCU. The defining feature of this unit is its ability to drive two independent ESB segments; utilize this by routing the \"Upper\" bus cable to one bank of I\/O nodes and the \"Lower\" bus cable to a separate bank. This reduces cable clutter and improves signal integrity by keeping segment lengths short.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eStrictly adhere to the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e10-meter maximum distance\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e\u003cspan\u003e \u003c\/span\u003elimit for each ESB cable run. Exceeding this length at 128 Mbps will result in data corruption and communication faults. Use only Yokogawa-certified ESB twisted-pair cables with proper shielding. Ensure termination resistors are installed at the physical end of\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003eeach\u003c\/em\u003e\u003cspan class=\"qwen-markdown-text\"\u003e\u003cspan\u003e \u003c\/span\u003eof the two bus segments (Upper and Lower) to prevent signal reflection. For the \"-1\" (Explosion Protected) variant, all wiring must comply with local hazardous area codes (e.g., NEC, ATEX, IECEx), utilizing approved seals, conduits, and grounding methods to maintain the integrity of the explosion protection system. Verify the 24 VDC power supply stability, as voltage dips can cause the ESB master to reset, disconnecting up to 18 I\/O units instantly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eFrequently Asked Questions (FAQ)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: What is the main advantage of the SEC402-51 over single-port couplers?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The SEC402-51 features two independent ESB ports (Upper and Lower). This allows a single module to control up to 18 I\/O units (9 per port) compared to 9 units on a single-port model. It effectively halves the number of coupler slots required in the FCU for high-density applications and simplifies cabinet wiring by splitting the load into two shorter, manageable cable runs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Can I mix standard and explosion-protected modules in the same rack?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: Yes, provided the rack installation location matches the highest safety requirement. If the rack is located in a hazardous area,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003eall\u003c\/em\u003e\u003cspan class=\"qwen-markdown-text\"\u003e\u003cspan\u003e \u003c\/span\u003emodules within that specific enclosure typically must meet the hazardous location rating. If the rack is in a safe area but controls field devices in a hazardous zone, the field wiring barriers determine the safety rating, not necessarily the backplane module. Consult your system integrator for specific zoning compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Is the SEC402-51 compatible with older CENTUM CS3000 systems?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The SEC402 series is primarily designed for the CENTUM VP platform. While Yokogawa maintains some backward compatibility, ESB bus architectures and firmware handshakes differ between CS3000 and VP. Using this module in a CS3000 system requires verifying the FCU type and firmware version; it is generally recommended for new VP installations or VP upgrades.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: What does the \"ISA G3\" certification mean for my application?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: ISA-71.04 Grade G3 indicates the module is built to withstand severe corrosive environments (e.g., high concentrations of sulfur dioxide, chlorine, or ammonia). If your plant is a wastewater treatment facility, pulp and paper mill, or coastal chemical plant, selecting the -G3 variant prevents premature failure of the circuit board due to atmospheric corrosion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: How do I troubleshoot if one of the two buses fails?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The CENTUM VP engineering station (Vx-Toolset) and Operator Station will report specific alarms distinguishing between \"Upper ESB Bus Error\" and \"Lower ESB Bus Error.\" Check the LED status on the module; typically, individual LEDs indicate the health of each port. Isolate the fault by checking the termination and cabling of the specific failed segment without affecting the operational status of the second bus.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52522703061301,"sku":"SEC402-51","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/SEC402-51.jpg?v=1775031426","url":"https:\/\/www.5gplc.com\/products\/centum-vp-yokogawa-sec402-51-esb-bus-coupler-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}