{"product_id":"centum-vp-yokogawa-aip423-hard-drive-module","title":"CENTUM VP | Yokogawa AIP423  Hard Drive Module","description":"\u003ch2\u003e\u003cspan class=\"qwen-markdown-text\"\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAIP423\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStyle S1 is a critical storage and system integrity component designed specifically for Yokogawa CENTUM VP Human Interface Stations (HIS) and Field Control Stations (FCS). In modern Distributed Control Systems (DCS), data loss due to hard drive failure can lead to catastrophic operational downtime and loss of historical process trends. The AIP423 resolves this vulnerability by providing a ruggedized, industrial-grade hard drive module optimized for continuous 24\/7 operation in harsh environments. Engineered to withstand wide temperature fluctuations and high vibration, this module ensures the reliable storage of control logic, configuration data, and long-term historical trends, serving as the foundational memory unit for stable plant operations in oil and gas, power generation, and chemical processing facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable class=\"qwen-markdown-table\"\u003e\n\u003cthead class=\"qwen-markdown-table-thead\"\u003e\n\u003ctr class=\"qwen-markdown-table-thead-tr firstRow\"\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eParameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"qwen-markdown-table-tbody\"\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eModel Number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eAIP423\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eStyle Code\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eS1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eManufacturer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eIndustrial Hard Drive Module \/ Storage Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSystem Compatibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eCENTUM VP, CENTUM CS 3000 (HIS\/FCS Units)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eInterface Protocol\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eProprietary DCS Bus \/ ATA Compatible (Internal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eData Transfer Rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eOptimized for high-speed DCS logging (Up to 100 Mbps equivalent throughput)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePower Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e24 VDC (Derived from Host Station Backplane)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eForm Factor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e19-inch Rack Mountable (via Host Station Chassis)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eDimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eStandard DCS Module Slot Width (Approx. 30mm W x 130mm H x 100mm D)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eUnit Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eApprox. 1.0 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e-10°C to +60°C (14°F to 140°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e-20°C to +70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eOperating Humidity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e10% to 90% RH (Non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eVibration Resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eCompliant with IEC 60068-2-6 (Industrial Grade)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eMTBF\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e\u0026gt;100,000 Hours (Typical for Industrial HDD)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eModel Code Decomposition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eYokogawa’s peripheral and storage modules utilize a specific suffix system to denote hardware revisions, capacity, and interface compatibility. The \"Style\" code is mandatory for ensuring the drive is recognized by the CENTUM VP BIOS and operating system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePart Number: AIP423-S1\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eAIP\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: The series prefix for CENTUM VP\/CS 3000 peripheral units, indicating standard I\/O, interface, or storage hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e423\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: The unique functional identifier for the Hard Drive Module.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e\"4\"\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e series often denotes mass storage or advanced interface units within the Yokogawa architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e\"23\"\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e sequence specifically identifies the form factor and capacity class suitable for HIS\/FCS system boot and historical data logging.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e-S1 (Style 1)\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: This suffix is critical and indicates the specific hardware revision and interface configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eS1\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Denotes the first major production revision of the AIP423, typically featuring a specific capacity (e.g., 40GB–80GB range depending on manufacturing era) and firmware mapping compatible with CENTUM VP R3.x and later systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCompatibility Note\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Substituting an S1 module with a different style (e.g., S2 or non-Yokogawa drives) without firmware reconfiguration will likely result in the station failing to boot or recognize the drive. The \"S1\" ensures pin-out alignment and voltage tolerance matching the original design specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eInstallation Recommendations and Wiring Guidelines\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eInstalling the AIP423 requires careful handling to prevent data corruption and physical damage to the storage media.\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eStatic Discharge Protection\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Hard drive modules contain sensitive electronic components. Always wear an ESD (Electrostatic Discharge) wrist strap when handling the AIP423 before inserting it into the HIS or FCS chassis.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSystem Shutdown\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: While some CENTUM VP components are hot-swappable, replacing a primary system hard drive usually requires a controlled shutdown of the specific station to prevent file system corruption. Ensure the station is powered down or in maintenance mode before insertion.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eBackplane Connection\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Slide the AIP423 firmly into the designated drive bay slot until the rear connector engages fully with the backplane. You should feel a distinct click or resistance indicating proper seating. Secure the front locking lever or mounting screws immediately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eInitialization \u0026amp; Formatting\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Upon first installation, the drive may need to be initialized using the CENTUM VP maintenance tools (e.g.,\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e or via the System View). \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eWarning\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: This process erases all existing data. Only perform this on new replacements or after successful data backup.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eThermal Monitoring\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: After installation, monitor the station's internal temperature via the diagnostic software. Ensure the chassis cooling fans are operational, as hard drives are sensitive to temperatures exceeding 60°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eData Migration\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: If replacing a failed drive in an existing system, use Yokogawa’s backup\/restore utilities to reload the system image and historical database from the latest backup tape or network image.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eFrequently Asked Questions (FAQ)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Can I use a standard commercial hard drive instead of the AIP423?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: No. The AIP423 is not a standard SATA\/IDE drive; it features a proprietary interface connector and firmware mapping specifically designed for the Yokogawa CENTUM VP backplane. Commercial drives will not physically fit or be recognized by the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: What does the \"S1\" suffix mean, and can I use an AIP423 without it?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The \"S1\" denotes the specific hardware revision and capacity configuration. You cannot order just \"AIP423\"; the style suffix is required to ensure compatibility with your specific CENTUM VP software version. Using an incorrect style may cause boot failures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Is the AIP423 hot-swappable?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: While the physical module can be inserted\/removed while the rack is powered, replacing the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cem\u003esystem\u003c\/em\u003e\u003cspan class=\"qwen-markdown-text\"\u003e\u003cspan\u003e \u003c\/span\u003ehard drive generally requires the station to be offline to prevent data corruption during the swap. It is recommended to perform this replacement during a planned maintenance window.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: How do I know if my AIP423 is failing?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: Signs of failure include frequent system crashes, inability to save historical trends, error messages regarding \"Disk Read\/Write Errors\" in the CENTUM VP diagnostics, or the station failing to boot past the BIOS screen.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Does this module come with the operating system pre-installed?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: New replacement AIP423 modules are typically shipped blank or with a factory base image. The end-user or system integrator must install the specific CENTUM VP system software and restore the site-specific configuration from backup.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52522127262005,"sku":"AIP423","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AIP423.jpg?v=1775026888","url":"https:\/\/www.5gplc.com\/products\/centum-vp-yokogawa-aip423-hard-drive-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}