{"product_id":"bmxxbe1000-schneider-electric-modicon-m340-backplane-expander-module","title":"BMXXBE1000 | Schneider Electric | Modicon M340 Backplane Expander Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eBMXXBE1000\u003c\/strong\u003e enables multi-rack expansion within the Modicon M340 automation platform. This standard-format backplane expander module links individual chassis into a unified multi-rack topology, allowing a single central processing unit (CPU) to control I\/O modules across different racks. By establishing a direct, high-speed extension of the X-bus backplane, the module provides structural scaling for extensive automation installations like centralized water distribution facilities, multi-stage conveyor networks, and localized factory floor processing cells.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBMXXBE1000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon M340 Automation Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccessory Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExtension Accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Expander Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBMXXBP0400 (4 slots)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eBMXXBP0600 (6 slots)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eBMXXBP0800 (8 slots)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eBMXXBP1200 (12 slots)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Destination\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-rack Configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x Female SUB-D 9 Connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard Diagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 x Green LED: Bus Operating Status (RUN)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e1 x Red LED: Rack Collision Error (COL)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e4 x Green LEDs: Rack Binary Address Status\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Demand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e22 mA at 3.3 V DC\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e160 mA at 24 V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Format Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Single-Slot Format\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIP Protection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Ambient Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32…140 °F (0…60 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10…95 % Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtective Treatment Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTC (Total Climate Treatment)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGlobal Trade Item Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGTIN: 3595863992175\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrance (FR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.102 oz (173.0 g)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless X-Bus Multi-Chassis Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLarge machinery installations often quickly exhaust the physical slot limits of a single automation rack. The BMXXBE1000 overrides this limitation by providing a master extension interface that links up to four separate BMXXBP series chassis (ranging from 4-slot to 12-slot bases). This layout allows the main processor to address distant physical points across the extended X-bus with zero software driver modifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual SUB-D 9 Daisy-Chain Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComplex physical panel layouts require clean, localized signal branching rather than long homerun wiring runs. This module incorporates two independent female SUB-D 9 connection ports directly onto its faceplate. This layout allows installers to daisy-chain extension cables from the primary CPU rack down to consecutive extension racks, optimizing wiring layouts inside crowded control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnboard Binary Address Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracking down configuration errors across a multi-drop rack network typically demands deep software diagnostic scans. The BMXXBE1000 speeds up this layout step by embedding four green rack address LEDs that display the physical binary address of the current rack. Maintenance crews verify hardware dip-switch matching instantly by checking the faceplate indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCollision Detection Data Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSignal interference or overlapping data bursts across extended buses can corrupt logic processing. The expander features a dedicated red Collision Error (COL) LED paired with internal tracking circuits. The module detects communication timing overruns or overlapping hardware signals instantly, triggering safe data retry cycles and protecting the main control loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTC-Certified Atmospheric Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMoisture and industrial gases degrade bare copper circuit traces, leading to premature backplane failures. The BMXXBE1000 features factory-applied TC (Total Climate) protective treatment. This chemical application seals internal components against humidity and corrosive plant environments, ensuring stable electrical contacts across the broad 10% to 95% non-condensing relative humidity spectrum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this BMXXBE1000 backplane expander card a 100% brand new item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this module strictly as a 100% brand new, original factory-sealed unit. It ships directly inside its authentic Schneider Electric commercial package, complete with all factory bar codes, original GTIN (3595863992175) label stickers, and factory anti-static wraps untouched.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this expander module occupy a standard I\/O slot or a special slot on the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BMXXBE1000 occupies the dedicated extension slot located on the far right end of the Modicon M340 BMXXBP backplane chassis. This clever location means it does not consume any of your active 4, 6, 8, or 12 application slots, preserving the maximum possible slot count for input, output, or network communication cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I construct an extension system using standard serial cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. To ensure reliable communication across multi-rack setups, you must utilize Schneider Electric's official double-shielded X-bus expansion cables terminated with male SUB-D 9 connectors. Standard commercial RS-232 or serial cables lack the critical line impedance, twisted-pair layout, and high-frequency shielding required to handle high-speed backplane signals safely without data loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require an external 24 V DC power feed from a terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The BMXXBE1000 draws its small operational power requirements—specifically 22 mA at 3.3 V DC and 160 mA at 24 V DC—directly from the internal backplane power supply (such as a BMXCPS module) seated on the local rack. You do not need to route auxiliary power conductors to the module faceplate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52909008552245,"sku":"BMXXBE1000","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BMXXBE1000.png?v=1779349536","url":"https:\/\/www.5gplc.com\/products\/bmxxbe1000-schneider-electric-modicon-m340-backplane-expander-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}