{"product_id":"bmxsdo0802-schneider-electric-modicon-x80-conformal-coated-discrete-output-module","title":"BMXSDO0802 | Schneider Electric | Modicon X80 Conformal Coated Discrete Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eBMXSDO0802 \u003c\/strong\u003edrives critical field actuators in highly corrosive and harsh processing zones within the Modicon X80 PAC infrastructure. This 8-point discrete solid-state output module operates on positive source logic to control solenoid valves, pilot lights, indicator panels, and magnetic contactors. Featuring heavy-duty factory conformal coating and strict gas, sand, and salt resistance certifications, this specialized card delivers precise actuator execution across wastewater facilities, offshore drilling platforms, chemical manufacturing plants, and harsh coastal environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBMXSDO0802\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon X80\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Output Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete Output Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePositive (Source configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum State 1 Voltage Drop\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 1.2 V at state 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Current per Channel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.625 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Total Current per Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eParalleling of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes - maximum of 2 outputs per group\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation Resistance Barrier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 10 MOhm at 500 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Strength Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1500 V AC at 50\/60 Hz for 1 minute (Output to ground)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e1500 V AC at 50\/60 Hz for 1 minute (Output to internal logic)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard Hardware Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, overvoltage, short-circuit, and reverse polarity protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Voltage Thresholds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 14 V DC (Sensor \/ auxiliary power supply fault)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u0026gt; 18 V DC (Sensor \/ auxiliary power supply OK)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMean Time Between Failures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e383,000 Hours (MTBF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIP Protection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5…95% up to 131 °F (55 °C) non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtective Finish Treatment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory-applied conformal coating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSevere Environment Resilience\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGas resistant Class Gx\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eGas resistant Class 3C4\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eDust resistant Class 3S4\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eSand resistant Class 3S4\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eSalt spray resistant Level 2\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eMold growth resistant Class 3B2\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eFungal spore resistant Class 3B2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg (0.264 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Class Severe Atmospheric Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAirborne hydrogen sulfide (\u003cspan class=\"math-inline\"\u003e$H_2S$\u003c\/span\u003e), chlorine fumes, salt mist, and blowing sand easily penetrate standard electrical cabinets, causing rapid corrosion on exposed PCB traces. The BMXSDO0802 stops atmospheric degradation by utilizing a specialized premium factory conformal coating. This treatment meets strict Class 3C4\/Gx gas resistance, Class 3S4 sand\/dust resistance, and Level 2 salt spray standards, preventing electrical shorts and contact oxidation in offshore or refinery applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBiological Resistance Against Mold and Fungi:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHumid, tropical installations or dark sub-grade utility vaults expose automation components to persistent biological fouling. Organic mold growth and fungal spores consume standard electronic insulating plastics, creating conductive carbon tracks that short-circuit hardware. The BMXSDO0802 features certified Class 3B2 mold and fungal spore resistance, containing bio-inhibiting properties that permanently suppress micro-organic growth to safeguard the output circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFourfold Solid-State Electrical Defense:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInductive voltage spikes from large solenoid coils or accidental field wiring shorts can fry sensitive output transistors instantly. The BMXSDO0802 integrates continuous overload, overvoltage, short-circuit, and reverse polarity protections directly onto every terminal path. If an external short circuit occurs, the module automatically restricts the fault current and disconnects the affected channel, keeping the remaining outputs running and protecting the internal backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Layer 1500 V Galvanic Safety Barrier:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-voltage lightning surges or direct cross-wiring errors on industrial plant floors can pass destructive feedback loops into central processing units. This module establishes a robust 1500 V AC dielectric isolation barrier for 1 minute between the field outputs and ground. It duplicates this 1500 V AC safety margin between the field terminals and the internal logic processing bus, completely separating raw field energy from the central PAC processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Sensor Power Detection Thresholds:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVoltage drops or loose connections in terminal loops can drop output relays out of sequence without triggering a standard system fault. This module incorporates continuous voltage tracking window diagnostics. If auxiliary sensor line power sags below 14 V DC, the module sets a system fault flag immediately to alert operators via the SCADA interface. The card restores normal operations only after line levels safely exceed 18 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this BMXSDO0802 discrete output module a brand new original item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this product exclusively as a 100% brand new, original factory-sealed unit. The module comes packed inside its original Schneider Electric corporate box with all factory seals intact, complete with anti-static packaging wraps and authentic serial number barcode stickers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I parallel multiple outputs to handle a higher current load device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The BMXSDO0802 supports the parallel wiring of up to a maximum of 2 output channels per group. This configuration allows you to combine the individual 0.625 A channel capacities safely to drive higher-current solenoid coils or actuator devices without overloading the module circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the conformal coating on this specific module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe conformal coating is a specialized thin polymer film applied directly to the internal printed circuit board assemblies during manufacturing. This coating creates an airtight, moisture-proof barrier that shields delicate electronic elements from chemical vapors, salt mist, humidity, mold growth, and fine dust particles, allowing the module to achieve its high 383,000-hour MTBF rating in severe environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external fuse for reverse polarity wiring protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The BMXSDO0802 contains an integrated internal reverse-mounted diode that handles reverse polarity protection natively. If an installation crew accidentally reverses the positive and negative 24 V DC auxiliary power wires on the terminal block, the onboard diode blocks the reverse current immediately to preserve the solid-state output circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52909106626869,"sku":"BMXSDO0802","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BMXSDO0802.png?v=1779352301","url":"https:\/\/www.5gplc.com\/products\/bmxsdo0802-schneider-electric-modicon-x80-conformal-coated-discrete-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}