{"product_id":"bmxcps2010-modicon-x80-dc-power-supply-module-schneider-electric","title":"BMXCPS2010 Modicon X80 DC Power Supply Module | Schneider Electric","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eBMXCPS2010\u003c\/strong\u003e drives regulated electrical power directly to standard Modicon X80 automation backplanes. Operating on an isolated 24 V DC primary input, this module converts raw field power into two highly stabilized secondary direct-current channels. It energizes the main CPU processors, communications networks, and adjacent I\/O hardware, serving as the core electrical backbone for remote telemetry units (RTUs), solar-powered field installations, and heavy-duty 24V control cabinets.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBMXCPS2010\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon X80\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated DC Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC isolated (Operational Limit: 18...31.2 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A at 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current Peak\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 A at 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Power (3.3V Logic)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.3 W DC (2.5 A) for I\/O module logic power supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Power (24V System)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.8 W DC (0.7 A) for I\/O module and processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRack Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard X80 racks (Not compatible with BMEXBP..02)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMean Time Between Failures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4,886,000 Hours (MTBF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Strength Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V between primary circuit, secondary circuit, and ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 rating with TC protective treatment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperational Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32…140 °F (0…60 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.64 lb (0.29 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSevere field voltage spikes easily migrate into control loops via shared DC links. The BMXCPS2010 eliminates this hazard by providing a robust 1500 V dielectric insulation barrier between the primary 24V supply circuit, the secondary backplane rails, and the chassis ground, protecting sensitive microprocessors from external field faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Multi-Fault Defensive Layer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDownstream field wiring short-circuits or module overloads can freeze a whole automation system. This power module incorporates independent, non-stop secondary overvoltage, overload, and short-circuit protection circuits that instantly isolate electrical faults to safeguard the backplane components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Immunity to Microbreaks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFluctuating DC networks often experience sudden voltage drops when heavy motors start up. The internal capacitor arrays of this module deliver 1 ms of continuous immunity to microbreaks, sustaining clean, uninterrupted processing power to prevent unexpected PLC resets during power sags.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal and Environmental Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module limits its maximum power dissipation to a low 8.5 W, reducing heat generation inside airtight field enclosures. Complemented by a TC protective treatment (tropicalization), the card resists moisture, corrosion, and ambient relative humidity up to 95%, operating reliably across a 0 to 60°C window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Field Wiring Distances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit accommodates long-distance remote panel deployments. Its primary input stage supports copper power supply cables extending up to 65.6 feet (20 m) using 1.5 mm² wire gauges, or up to 98.4 feet (30 m) using 2.5 mm² conductors, minimizing voltage drop degradation across long runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this BMXCPS2010 power supply a brand new unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We sell this product exclusively as a 100% brand new, original factory unit. It ships direct in the original manufacturer sealed box with all production quality stickers and installation guides intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I run this module on a standard 110V or 220V AC utility line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module accepts only a direct-current input. It requires a stable 24 V DC source and operates within a strict input voltage window of 18 V DC to 31.2 V DC. Connecting an AC line supply will permanently destroy the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this power supply slot into the Ethernet-enabled BMEXBP series backplanes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The BMXCPS2010 fits standard Modicon X80 racks. It is explicitly incompatible with the hybrid Ethernet backplanes starting with the prefix code \"BMEXBP..02\". Verify your rack model prefix before performing installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat function does the front mechanical button perform?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe front face houses a dedicated RESET push-button. Pressing this button executes a cold restart of the rack system, allowing field technicians to clear software locks or initialize hardware states directly at the enclosure without toggling the primary field breakers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52908633686325,"sku":"BMXCPS2010","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BMXCPS2010.png?v=1779342931","url":"https:\/\/www.5gplc.com\/products\/bmxcps2010-modicon-x80-dc-power-supply-module-schneider-electric","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}