{"product_id":"bently-nevada-temperature-monitor-module-3500-60-01-00","title":"Bently Nevada Temperature Monitor Module | 3500\/60-01-00","description":"\u003cp\u003eThe Bently Nevada \u003cstrong\u003e3500\/60-01-00\u003c\/strong\u003e Temperature Monitor is a six-channel machinery protection module designed to accept both Resistance Temperature Detector (RTD) and Thermocouple (TC) inputs. This specific configuration pairs the base monitor with a -01 non-isolated RTD\/TC I\/O module featuring internal terminations, while omitting hazardous agency approvals (-00 option). It continuously conditions sensor inputs and compares them against user-programmable alarm thresholds to protect critical rotating assets.\u003c\/p\u003e\n\u003ch3\u003eChannel Inputs and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe module supports up to six independent temperature measurement channels, configurable for multiple sensor types including platinum, nickel, or copper RTDs, as well as various thermocouple standards (Types E, J, K, and T). Input signals are processed through high-impedance circuitry to maintain measurement integrity across long cable runs.\u003c\/p\u003e\n\u003cp\u003eThe configuration software allows engineers to define full-scale temperature ranges, scale factors, and specific sensor characteristics for each channel independently.\u003c\/p\u003e\n\u003ch3\u003eAlarm Management and System Integration\u003c\/h3\u003e\n\u003cp\u003eReal-time temperature data is evaluated continuously against programmable Alert and Danger setpoints. The module features adjustable time delays to prevent nuisance tripping during temporary thermal transients.\u003c\/p\u003e\n\u003cp\u003eAs part of the \u003cstrong\u003e3500\/60\u003c\/strong\u003e series without recorder outputs, this unit relies on digital communication via the rack interface module to transmit data to automation systems, avoiding dedicated analog retransmission loops. Front-panel LED indicators display operational readiness, channel status, and communication traffic.\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/60-01-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3500\/60 Temperature Monitor Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e6 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Inputs\u003c\/td\u003e\n\u003ctd\u003eRTD (Platinum, Nickel, Copper) and Thermocouple (Types E, J, K, T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Type\u003c\/td\u003e\n\u003ctd\u003e-01 RTD\/TC Non-isolated I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e-00 None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the \u003cstrong\u003e3500\/60-01-00\u003c\/strong\u003e provide 4 to 20 mA recorder outputs?\u003c\/p\u003e\n\u003cp\u003eA: No, this specific variant belongs to the non-recorder product line, meaning proportional analog outputs are omitted in favor of digital communication through the 3500 framework.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module accept mixed input types across its six channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes, channels can be configured independently to accept compatible RTD or thermocouple sensors depending on plant monitoring requirements.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68024618746165,"sku":"3500\/60-01-00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/350065-01-01_8dda26f2-5bff-4098-bd00-fae8de6e0a3f.png?v=1793686564","url":"https:\/\/www.5gplc.com\/products\/bently-nevada-temperature-monitor-module-3500-60-01-00","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}