{"product_id":"bently-nevada-3500-20-01-02-00-125744-02-125768-01-rack-interface-module","title":"Bently Nevada 3500\/20-01-02-00 (125744-02+125768-01) Rack Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003e3500\/20-01-02-00\u003c\/strong\u003e Rack Interface Module is a core component designed for the Bently Nevada 3500 machinery protection system. This module manages communications between the rack and external configuration software, system monitors, and external automation systems. It features a standard rack interface type 01 combined with an I\/O module providing RS232 and RS422 serial interfaces for external data integration.\u003c\/p\u003e\n\u003ch3\u003eCore Architecture and Functions\u003c\/h3\u003e\n\u003cp\u003eThe Rack Interface Module (RIM) resides in a dedicated slot in the 3500 rack and functions as the primary communication gateway. It gathers status and diagnostic information from all other modules within the rack and distributes rack configuration data to individual monitor modules. This model supports standard monitoring configurations without requiring specialized proprietary protocols for basic data extraction.\u003c\/p\u003e\n\u003ch3\u003eCommunication and I\/O Configuration\u003c\/h3\u003e\n\u003cp\u003eThe integrated I\/O module features serial communication capabilities via RS232 and RS422 interfaces. These ports allow connection to configuration software running on a host computer or integration with distributed control systems using supported communication protocols. The hardware setup ensures reliable command execution and event data collection across the rack architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9986%; height: 209.416px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003cth style=\"width: 30.0182%; height: 19.5833px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 67.2245%; height: 19.5833px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 13.5833px;\"\u003e\n\u003ctd style=\"width: 30.0182%; height: 13.5833px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 67.2245%; height: 13.5833px;\"\u003e3500\/20-01-02-00 (125744-02+125768-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 30.0182%; height: 19.5833px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 67.2245%; height: 19.5833px;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 30.0182%; height: 19.5833px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"width: 67.2245%; height: 19.5833px;\"\u003eRack Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 30.0182%; height: 19.5833px;\"\u003eRack Interface Type\u003c\/td\u003e\n\u003ctd style=\"width: 67.2245%; height: 19.5833px;\"\u003e01 (Standard RIM for standard monitoring applications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 30.0182%; height: 19.5833px;\"\u003eI\/O Module Type\u003c\/td\u003e\n\u003ctd style=\"width: 67.2245%; height: 19.5833px;\"\u003e02 (I\/O module with RS232\/RS422 interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1667px;\"\u003e\n\u003ctd style=\"width: 30.0182%; height: 39.1667px;\"\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd style=\"width: 67.2245%; height: 39.1667px;\"\u003e00 (None)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 30.0182%; height: 19.5833px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 67.2245%; height: 19.5833px;\"\u003e1.36 kg (0.91 kg + 0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 30.0182%; height: 19.5833px;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"width: 67.2245%; height: 19.5833px;\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 30.0182%; height: 19.5833px;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"width: 67.2245%; height: 19.5833px;\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the 3500\/20-01-02-00 module in a 3500 rack?\u003c\/p\u003e\n\u003cp\u003eA: It acts as the central communication hub, managing data exchange between the rack monitors and external configuration software or control systems.\u003c\/p\u003e\n\u003cp\u003eQ: What type of serial communication does the included I\/O module support?\u003c\/p\u003e\n\u003cp\u003eA: The associated I\/O module supports RS232 and RS422 serial interfaces for external connectivity.\u003c\/p\u003e\n\u003cp\u003eQ: Can this specific RIM configuration be used with hazardous area agency approvals?\u003c\/p\u003e\n\u003cp\u003eA: No, this specific model configuration uses agency approval option 00, indicating no hazardous area approvals are included.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68019215171893,"sku":"3500\/20-01-02-00(125744-02+125768-01)","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/350022M288055-01_d911a080-792f-4246-9d44-7da0c9d37986.jpg?v=1793605321","url":"https:\/\/www.5gplc.com\/products\/bently-nevada-3500-20-01-02-00-125744-02-125768-01-rack-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}