{"product_id":"bently-nevada-3500-05-01-01-00-00-00-system-rack","title":"Bently Nevada 3500\/05-01-01-00-00-00 System Rack","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/05-01-01-00-00-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3500\/05\u003c\/strong\u003e System Rack, operates as a dedicated hardware component for physical module mounting and backplane bus signal routing within 3500 Series Machinery Protection System platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Field\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Size\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mount (16 slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e19-inch EIA rack mounting format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone \/ Standard non-certified configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReserved Option 1\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eUnassigned \/ Standard default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReserved Option 2\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eUnassigned \/ Standard default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/05-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.54 kg (10.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 19-inch EIA rack width, 16-slot capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C (-22 deg F to +149 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive chassis backplane structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Architecture\u003c\/td\u003e\n\u003ctd\u003eHigh-speed internal backplane communications bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Density\u003c\/td\u003e\n\u003ctd\u003e16 module slots (Slot 0 reserved for Power Supply, Slot 1 for RIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/05 16-slot chassis provides high-density backplane signal pathways that route raw eddy-current probe voltage and dynamic vibration waveforms directly between monitor modules and keyphasor inputs. Integrated shielding plane geometry inside the multilayer backplane printed circuit board maintains cross-talk suppression between adjacent high-frequency dynamic channels. This signal integrity enables accurate rotor dynamics monitoring and gap voltage validation across full-scale machine monitoring operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can modules be inserted or removed from the 3500\/05 backplane while power is applied?\u003c\/p\u003e\n\u003cp\u003eA: Yes, modules designed for the 3500 Series system support hot-swapping within the 3500\/05 rack without interrupting operation of unaffected slots or causing backplane signal corruption.\u003c\/p\u003e\n\u003cp\u003eQ: How is chassis grounding managed across the 16 slots of the 3500\/05 chassis?\u003c\/p\u003e\n\u003cp\u003eA: The rack frame features a central earth ground bonding stud on the rear enclosure to maintain equipotential reference across all installed card guides and signal shields.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the 19-inch 3500\/05 chassis into a standard EIA instrument rack using appropriate panel mounting hardware.\u003c\/li\u003e\n\u003cli\u003eConnect a dedicated heavy-gauge grounding conductor from the chassis earth ground stud on the rear of the rack to the main station ground bar.\u003c\/li\u003e\n\u003cli\u003eEnsure slot 0 is populated with a 3500 Power Supply module and slot 1 contains the Rack Interface Module (RIM) before installing monitoring cards.\u003c\/li\u003e\n\u003cli\u003eInsert monitor modules along card guides until the backplane connectors seat completely, then tighten upper and lower front-panel thumbscrews.\u003c\/li\u003e\n\u003cli\u003eRoute dynamic signal wires away from high-voltage field wiring to prevent electromagnetic interference coupling into the backplane.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53209229852981,"sku":"3500\/05\/01-01-00-00-00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/35000501-01-00-00-00_edb12995-b6d9-40d0-92ed-08892ec95af5.png?v=1784799272","url":"https:\/\/www.5gplc.com\/products\/bently-nevada-3500-05-01-01-00-00-00-system-rack","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}