{"product_id":"bently-nevada-330104-00-02-50-02-00-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330104-00-02-50-02-00 3300 XL 8 mm Proximity Probe","description":"\u003cp\u003eThe \u003cstrong\u003e330104-00-02-50-02-00\u003c\/strong\u003e is an 8 mm proximity probe from Bently Nevada, operating as a dedicated eddy-current sensing element for rotor-to-probe displacement measurement within 3300 XL vibration monitoring systems. This configuration features a 0 mm unthreaded length, a 20 mm overall case length, and a 5.0-meter signal path. It provides stable mechanical-to-electrical transduction for industrial rotating machinery protection.\u003c\/p\u003e\n\u003ch3\u003eConstruction and Core Performance\u003c\/h3\u003e\n\u003cp\u003eThe probe is constructed with a polyphenylene sulfide tip, a stainless-steel housing, and a Viton O-ring seal to withstand harsh operating conditions. The PPS tip and stainless-steel case maintain stable eddy-current field geometry, reducing thermal drift while supporting the standard -10 VDC gap voltage target across proximitor interfaces.\u003c\/p\u003e\n\u003ch3\u003eConfiguration and Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe part number structure designates a 20 mm case length combined with an extended 5.0-meter standard cable terminated with a miniature coaxial ClickLoc connector. The final -00 suffix indicates that agency approvals are not required for this particular unit configuration.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-02-50-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm (-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e20 mm (-02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft) (-50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector and Cable Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (-02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eNot required (-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel (SST) with Viton O-ring sealing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive eddy-current probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eField Installation Guidelines\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMaintain straight, strain-relieved routing of the 5.0-meter cable and avoid tight bends near the ClickLoc connector to preserve coaxial impedance.\u003c\/li\u003e\n\u003cli\u003eEnsure the probe tip is aligned perpendicular to the rotor surface and verify the gap voltage during commissioning to confirm correct mechanical positioning.\u003c\/li\u003e\n\u003cli\u003eBond cable shielding at the driver end only to prevent ground-loop interference.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Does the probe require a specific extension cable length for correct scaling?\u003c\/p\u003e\n\u003cp\u003eA: Yes, eddy-current probes must be paired with the exact cable length defined by the part number to maintain -10 VDC gap voltage calibration.\u003c\/p\u003e\n\u003cp\u003eQ: Is the Viton O-ring pressure-tested before shipment?\u003c\/p\u003e\n\u003cp\u003eA: No, standard probes are not pressure-tested; applications requiring verified sealing should utilize custom-tested units.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68179028836661,"sku":"330104-00-02-50-02-00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/330103-00-03-10-02-00_b3045b5c-0d62-416e-b892-3fa8e4353aa6.jpg?v=1794385856","url":"https:\/\/www.5gplc.com\/products\/bently-nevada-330104-00-02-50-02-00-3300-xl-8-mm-proximity-probe","provider":"High Five Auto Solution Limited","version":"1.0","type":"link"}