{"product_id":"bently-nevada-330101-00-16-10-02-cn-3300-xl-8-mm-proximity-probes","title":"Bently Nevada 330101-00-16-10-02-CN 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eConfigured for dynamic fluid-film bearing displacement and shaft position measurement in machinery protection platforms, the \u003cstrong\u003eBently Nevada 330101-00-16-10-02-CN\u003c\/strong\u003e (\u003cstrong\u003e330101\u003c\/strong\u003e Proximity Probe) provides direct physical voltage modulation through radio-frequency eddy-current observation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Field\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0.0 in unthreaded case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e1.6 in total case length (3\/8-24 UNF thread)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet) integrated cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector \/ Cable\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry-specific certification approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330101-00-16-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.323 kg (Shipping weight: 1.30 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF thread, 1.6 in overall case length, 1.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C (-60 deg F to +351 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive transducer component (powered via Proximitor Sensor loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Linear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting at 0.25 mm (10 mils) offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe operates by generating a high-frequency magnetic field at the tip, inducing eddy currents in the metallic target surface. Sensor output scales at a calibrated nominal linear transfer function of 7.87 V\/mm (200 mV\/mil) when paired with matching 3300 XL Proximitor Sensors and extension cables. Target mechanical positioning verification requires DC gap voltage validation using a calibrated multimeter. Standard installation targets a center-gap voltage output of -10 VDC across the Proximitor signal terminals, corresponding to approximately 1.27 mm (50 mils) physical standoff from carbon steel targets (AISI 4140).\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the mandatory electrical constraint when connecting this probe to a 3300 XL Proximitor Sensor?\u003c\/p\u003e\n\u003cp\u003eA: The probe system total length must strictly match the calibrated system length (1.0 meter probe combined with matching extension cable to reach 5.0 meter or 9.0 meter system total tuning). Deviations alter system capacitance and cause scale factor distortion.\u003c\/p\u003e\n\u003cp\u003eQ: How does the ClickLoc connector maintain electrical integrity in high-vibration environments?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc coaxial connector utilizes a keyway locking mechanism designed to prevent self-loosening under structural vibration. Connection integrity requires tightening until an audible click engagement is verified.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect thread engagements prior to insertion; ensure mounting tapped hole is free of debris to prevent binding on the 3\/8-24 UNF stainless steel case.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum unthreaded target clearance area around the probe tip of 30 mm (1.2 in) diameter to avoid lateral metallic cross-talk干扰 or structural interference.\u003c\/li\u003e\n\u003cli\u003eTighten probe mounting locknuts using standard mechanical torque limits; do not exceed 3.4 N-m (30 in-lb) on the 3\/8-24 threads.\u003c\/li\u003e\n\u003cli\u003eSet mechanical probe gap while observing the DC gap voltage at the monitor or Proximitor test points. Adjust physical position until voltage reads -10.0 VDC +\/- 0.5 VDC.\u003c\/li\u003e\n\u003cli\u003eConnect ClickLoc coaxial connectors cleanly. Apply protective silicone insulation boots over coaxial connectors to isolate electrical connections from ground potential and fluid ingress.\u003c\/li\u003e\n\u003cli\u003eRoute probe cabling through dedicated grounded conduit or cable trays. Maintain separation from AC power lines and high-voltage drive conductors to prevent electromagnetic noise coupling.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53208722178357,"sku":"330101-00-16-10-02-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/330101-00-16-10-02-CN.png?v=1784796019","url":"https:\/\/www.5gplc.com\/products\/bently-nevada-330101-00-16-10-02-cn-3300-xl-8-mm-proximity-probes","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}