{"product_id":"bently-nevada-1900-65a-01-00-01-00-00-general-purpose-equipment-monitor","title":"Bently Nevada 1900\/65A-01-00-01-00-00 General Purpose Equipment Monitor","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 1900\/65A-01-01-00-00\u003c\/strong\u003e (part number 1900\/65A-01-00-01-00-00) is a general-purpose machinery monitor designed for continuous condition monitoring and protection of non-critical equipment. Powered by a 18 to 36 VDC supply, it evaluates dynamic vibration, position, and thermal inputs to trigger protective relay alarms.\u003c\/p\u003e\n\u003ch3\u003eSensor Inputs and Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe monitor features four dedicated transducer inputs supporting 2-wire and 3-wire accelerometers, velocity sensors, and proximity probes. Additionally, four temperature channels accommodate 2-wire or 3-wire RTDs as well as Type E, J, K, and T thermocouples for comprehensive thermal monitoring.\u003c\/p\u003e\n\u003ch3\u003eOutput Interfaces and Option Configuration\u003c\/h3\u003e\n\u003cp\u003eFor system outputs, the unit provides six alarm relays, four configurable 4-20 mA recorder outputs, and a dedicated buffered output for direct raw signal analysis. Built-in Modbus communication operates over Ethernet and RS232\/RS485 serial ports. The complete option breakdown for this configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e01 (Power Option):\u003c\/strong\u003e 18 to 36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00 (Display Option):\u003c\/strong\u003e No display (Note: raw text lists attached display)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01 (Mounting Option):\u003c\/strong\u003e DIN rail mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00 (Approvals Option):\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00 (Communications Option):\u003c\/strong\u003e None\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1900\/65A-01-00-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eGeneral Purpose Equipment Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels (2- and 3-wire accelerometers, velocity sensors, proximity probes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels (RTDs 2\/3-wire, Thermocouples Type E, J, K, T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e6 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003e4 configurable 4-20 mA outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Output\u003c\/td\u003e\n\u003ctd\u003eDedicated transducer signal buffered output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus via Ethernet and RS232\/RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power input and mounting style are configured for the 1900\/65A-01-00-01-00-00 monitor?\u003c\/p\u003e\n\u003cp\u003eA: This model configuration is powered by an 18 to 36 VDC supply and is built for direct DIN rail mounting inside control panels.\u003c\/p\u003e\n\u003cp\u003eQ: What temperature sensors can be connected to the temperature input channels?\u003c\/p\u003e\n\u003cp\u003eA: The four temperature channels support 2-wire and 3-wire RTDs, as well as Type E, J, K, and T thermocouples.\u003c\/p\u003e\n\u003cp\u003eQ: What outputs are available for field recording and diagnostic tools?\u003c\/p\u003e\n\u003cp\u003eA: The unit provides four configurable 4-20 mA recorder outputs for trend monitoring and a dedicated buffered output for connecting diagnostic instruments.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":67965249945909,"sku":"1900\/65A-01-00-01-00-00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/190065A167699-021_ab6b1625-9385-48b5-a850-9e6aeb074452.png?v=1793072922","url":"https:\/\/www.5gplc.com\/products\/bently-nevada-1900-65a-01-00-01-00-00-general-purpose-equipment-monitor","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}