{"product_id":"bc810k01-3bse03115r1-abb-cex-bus-interconnection-units","title":"BC810K01 3BSE03115R1 | ABB | CEX-bus Interconnection Units","description":"\u003cp\u003eThe \u003cstrong\u003eABB BC810K01 3BSE03115R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBC810K01\u003c\/strong\u003e Communication Modules, operates as a dedicated hardware component for section partitioning and extension of the CEX-bus communication backplane within System 800xA and AC 800M controller configurations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBC810K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Code\u003c\/td\u003e\n\u003ctd\u003e3BSE03115R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Kit Components\u003c\/td\u003e\n\u003ctd\u003eBC810 Interconnection Unit, TP857 Baseplate (width 60 mm), TB850 CEX-Bus Terminator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.77 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e59 mm x 127.5 mm x 185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via controller CEX-bus baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eFollowing EU Directive 2011\/65\/EU (RoHS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication \u0026amp; Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe ABB BC810K01 interconnection kit permits the division or extension of the CEX-bus segment, allowing redundant controller setups and isolated communication layouts without degrading signal propagation velocity. Installed on the TP857 baseplate, the module retains strict backplane bus communication timing across connected communication interfaces. Coupled with the TB850 bus terminator, the assembly maintains signal line termination standards required to prevent data frame reflection and preserve deterministic network performance during intense I\/O scan traffic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What items are supplied in the BC810K01 interconnection unit kit assembly?\u003c\/p\u003e\n\u003cp\u003eA: The BC810K01 kit includes the BC810 interconnection module, one 60 mm TP857 baseplate, and one TB850 CEX-bus terminator.\u003c\/p\u003e\n\u003cp\u003eQ: Can the BC810 module be removed from the TP857 baseplate while power is supplied to the CEX-bus?\u003c\/p\u003e\n\u003cp\u003eA: Power to the CEX-bus section must be removed prior to module removal or insertion to prevent communication interruption and electrical transients across the processor baseplate bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect control power to the processor rack and connected CEX-bus baseplates before installing the TP857 baseplate.\u003c\/li\u003e\n\u003cli\u003eMount the 60 mm TP857 baseplate securely onto the standard DIN rail alongside adjacent AC 800M system baseplates.\u003c\/li\u003e\n\u003cli\u003eAlign the rear connectors of the BC810 module with the TP857 baseplate socket and slide firmly into position until locked.\u003c\/li\u003e\n\u003cli\u003eInstall the TB850 CEX-bus terminator at the designated open physical end of the bus segment to ensure impedance balance.\u003c\/li\u003e\n\u003cli\u003eVerify that all shield wiring and cabinet grounding points are connected to the central protective earth busbar prior to applying operating voltage.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53221754732853,"sku":"BC810K01 3BSE03115R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BC810K013BSE03115R1.png?v=1785220108","url":"https:\/\/www.5gplc.com\/products\/bc810k01-3bse03115r1-abb-cex-bus-interconnection-units","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}