{"product_id":"bachmann-gio212-universal-input-output-module","title":"Bachmann GIO212 Universal Input\/Output Module","description":"\u003cp\u003eConfigured for versatile signal processing in M1 automation platforms, the \u003cstrong\u003eBachmann GIO212\u003c\/strong\u003e (\u003cstrong\u003eGIO212\u003c\/strong\u003e Universal Input\/Output Module) provides direct physical\/electrical execution of mixed-signal I\/O tasks including analog measurement, digital logic control, and PWM output modulation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGIO212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 mm x 12 mm x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e12 (up to 24 configurable functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bit (input), 14 bit (output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V (system galvanic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe GIO212 interfaces with the M1 rack backplane to facilitate deterministic network connectivity for real-time signal acquisition and control. The module utilizes high-speed backplane bus communication velocity to ensure synchronization between analog-to-digital conversion cycles and the controller CPU scan. The GIO212 supports advanced I\/O density scaling, enabling a single module to replace multiple dedicated I\/O cards by mapping different signal types (Pt100, thermocouple, analog, digital) per channel. Firmware flash compatibility is supported, allowing for runtime updates to signal filter characteristics and measurement mode logic without requiring hardware replacement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support simultaneous signal types on a single channel?\u003c\/p\u003e\n\u003cp\u003eA: Yes, up to two signal types can be active per channel, allowing for concurrent measurement and monitoring of analog sensors and digital signal states.\u003c\/p\u003e\n\u003cp\u003eQ: Are the digital outputs protected against electrical faults?\u003c\/p\u003e\n\u003cp\u003eA: Yes, all digital outputs are designed to be overload-proof, short-circuit-proof, and external-voltage-proof, with integrated diagnostic reporting for overtemperature and supply undervoltage.\u003c\/p\u003e\n\u003cp\u003eQ: Can the outputs be configured for stepper motor control?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the frequency mode allows for the generation of pulse trains for stepper motor output stages, with support for pulse counting and profile-based execution stored in a 1022-value FIFO buffer.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Wiring\u003c\/strong\u003e: When using Pt100\/Pt1000 sensors, utilize 4-wire measurement configurations where possible to compensate for lead resistance. Shielded cabling is mandatory for thermocouples and low-level analog signals to ensure 16-bit measurement accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltering\u003c\/strong\u003e: Adjust the channel-specific digital filters (ranging from 4 kHz down to 0.5 Hz) based on the noise environment and required response time to prevent signal aliasing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ensure the GIO212 backplane interface is securely seated and connected to the common system functional earth (FE) to maintain the 500 V galvanic isolation integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Monitoring\u003c\/strong\u003e: Connect the 24 VDC power supply to the designated terminals and monitor the diagnostic status bits for undervoltage conditions, which can invalidate analog measurement ranges.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":53025263124789,"sku":"GIO212","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/GIO212.png?v=1782118553","url":"https:\/\/www.5gplc.com\/products\/bachmann-gio212-universal-input-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}