{"product_id":"bachmann-do232-digital-output-module","title":"Bachmann DO232 Digital Output Module","description":"\u003cp\u003eConfigured for digital signal switching and actuator control in M1 automation platforms, the \u003cstrong\u003eBachmann DO232\u003c\/strong\u003e (\u003cstrong\u003eDO232\u003c\/strong\u003e Digital Output Module) provides direct physical\/electrical execution of load switching for relays, contactors, and valves.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e102 mm x 12 mm x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Quantity\u003c\/td\u003e\n\u003ctd\u003e32 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current\u003c\/td\u003e\n\u003ctd\u003e1 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eShort-circuit, cable break, overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe DO232 module interfaces with the M1 rack backplane to facilitate deterministic network connectivity for real-time actuator control. It leverages backplane bus communication velocity to ensure minimal latency during state transitions, maintaining consistency across the control loop. The architecture supports I\/O density scaling, allowing the module to manage up to 32 discrete loads within a single rack slot. Firmware flash compatibility is supported, ensuring that the diagnostic logic for fault detection—including short-circuit, cable break, and overload monitoring—remains synchronized with system-level control updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the outputs parallel connectable for higher load current requirements?\u003c\/p\u003e\n\u003cp\u003eA: Yes, outputs on the DO232 are parallel connectable to increase the total current capacity for specific loads, provided they are configured for the same operational mode.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle fault detection?\u003c\/p\u003e\n\u003cp\u003eA: The module includes integrated monitoring for short-circuit, cable break, and overload conditions. Detected faults are signaled to the controller to initiate safe-state execution for the connected actuators.\u003c\/p\u003e\n\u003cp\u003eQ: Is the output voltage fixed at 24 VDC?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the DO232 provides 24 VDC outputs designed for standard industrial actuators such as relays, contactors, and solenoid valves.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Use appropriately sized wire to handle the 1 A per channel load. Ensure cable shields are connected to the cabinet functional earth (FE) to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Loads\u003c\/strong\u003e: When switching inductive loads such as solenoid valves or contactors, ensure external suppression diodes or RC snubbers are installed to protect the output drivers from flyback voltage transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Segregation\u003c\/strong\u003e: Maintain physical separation between output signal wiring and high-voltage power lines to prevent induced noise and cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity\u003c\/strong\u003e: Periodically inspect terminal block connections for tightness, as vibration in industrial environments can lead to high-resistance contacts that trigger false overload diagnostics.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":53025247920437,"sku":"DO232","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DO2322.png?v=1782117601","url":"https:\/\/www.5gplc.com\/products\/bachmann-do232-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}