{"product_id":"bachmann-bs207-backplane-module","title":"Bachmann BS207 Backplane Module","description":"\u003cp\u003eConfigured for mechanical mounting and electrical interconnection in M200 system platforms, the \u003cstrong\u003eBachmann BS207\u003c\/strong\u003e (\u003cstrong\u003eBS207\u003c\/strong\u003e Backplane Module) provides direct physical\/electrical execution for module housing and bus distribution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann BS207\u003c\/strong\u003e is a fixed-slot backplane component. The model identifier \"207\" denotes the total count of available interface slots within the standard M200 form factor. No hardware suffixes exist for this model; it is provided as a standalone structural and communication distribution unit.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBS207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e38.7 cm x 2.5 cm x 12.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Bus routing only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slots\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Support\u003c\/td\u003e\n\u003ctd\u003eFASTBUS \/ M200 Internal Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane bus communication velocity Licences\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann BS207\u003c\/strong\u003e serves as the passive physical infrastructure required for high-speed deterministic communication across the M200 modular system. It facilitates the distribution of the backplane bus signals to all seven slots, maintaining signal integrity for communication velocities compliant with Bachmann processor specifications. The physical design supports the standardized bus expansion, ensuring that data transmission between the CPU and I\/O modules adheres to latency requirements without additional signal conditioning. The interconnection architecture is designed to support modular system expansion while maintaining alignment with internal bus impedance standards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the BS207 backplane include active switching components or microprocessors?\u003c\/p\u003e\n\u003cp\u003eA: No, the BS207 is a passive interconnection device. It serves as a mechanical support and electrical bus distributor for modules installed in its seven slots.\u003c\/p\u003e\n\u003cp\u003eQ: Is it possible to chain multiple BS207 backplanes together?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the backplane supports system expansion through standardized bus extension cables, provided the total system bus length does not exceed the communication specification limits of the host controller.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Stability\u003c\/strong\u003e: Secure the \u003cstrong\u003eBachmann BS207\u003c\/strong\u003e backplane to a grounded DIN-rail or flat mounting plate within the control cabinet. Use the integrated mounting points to ensure the unit is mechanically rigid to withstand vibration profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion\u003c\/strong\u003e: Ensure that all power is removed from the system before seating any I\/O or processor modules into the seven available slots. Align the module guide rails carefully to prevent damage to the backplane connector pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Establish a clean electrical connection between the backplane chassis and the cabinet ground bus. This is critical for electromagnetic compatibility (EMC) and to provide a reference potential for the module shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Constraints\u003c\/strong\u003e: Ensure that the cabling for bus expansion does not run parallel to high-voltage AC power lines. Maintain a minimum separation distance as defined by standard industrial electrical codes to prevent induced noise on the backplane communication lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Integrity\u003c\/strong\u003e: Inspect the interface connectors for bent pins or debris before module installation. Ensure that unused slots are covered with appropriate dust-protection blanks if operating in high-particulate environments.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":53025320763701,"sku":"BS207","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BS2071.png?v=1782120210","url":"https:\/\/www.5gplc.com\/products\/bachmann-bs207-backplane-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}