{"product_id":"anb10d-420-cu2n-ndel-yokogawa-duplicated-node-interface-unit","title":"ANB10D-420\/CU2N\/NDEL | Yokogawa Duplicated Node Interface Unit","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-420\/CU2N\/NDEL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDuplicated Node Interface Unit (NIU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS). This unit functions as a remote or local I\/O subrack, housing up to 8 FIO (Field Input\/Output) modules. The \"D\" designation indicates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDuplexed (Redundant)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture, providing dual paths for power and communication. This specific configuration includes specialized option codes (\u003cstrong\u003eCU2N\/NDEL\u003c\/strong\u003e) typically associated with refined communication terminal settings and specific hardware labeling for international project standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original Factory Sealed.\u003c\/p\u003e\n\u003ch2\u003ePart Number Breakdown: ANB10D-420\/CU2N\/NDEL\u003c\/h2\u003e\n\u003cp\u003eYokogawa utilizes a comprehensive suffix and option code system to define the NIU's electrical and physical properties:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eANB10D:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuplicated Node Interface Unit (for FIO).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant 100-120 V AC Power Supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19-inch Rack-mount type with insulation bushing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic hardware type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/CU2N:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication interface option (often specifying connector types or noise filtering).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/NDEL:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecialized labeling or destination-specific hardware designation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe ANB10D-420 provides a stable and redundant electrical environment for critical I\/O modules.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of I\/O Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 slots (supports Analog, Digital, and Communication FIO modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Bus:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eESB Bus (Extended Serial Backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100-120 V AC, 50\/60 Hz (Dual-redundant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 19-inch rack-mount (with insulation bushing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstand Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC between power terminals and ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax 100 VA (at 100-120 V AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports dual\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW481\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower units and dual\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEC401\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebus modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMission-Critical Availability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ANB10D-420\/CU2N\/NDEL is engineered to eliminate single points of failure. By utilizing dual-redundant power supplies and ESB bus interfaces, the unit ensures that all 8 I\/O modules remain online even if one power circuit or communication cable fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"2\" in the suffix indicates the inclusion of insulation bushings for rack mounting. This prevents ground loops and electrical noise from the cabinet frame from interfering with sensitive analog and digital signals, a critical requirement for E-E-A-T compliant industrial installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Distributed I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis NIU allows for the physical distribution of I\/O modules across the plant. By connecting multiple ANB10D units via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eESB bus cables, a single controller can manage widely dispersed field points while maintaining high-speed data synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnline Hardware Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll redundant components are hot-swappable. Maintenance teams can replace a faulty power supply or bus interface module while the system is live and the process is running, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Rack Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith 8 dedicated slots in a 19-inch form factor, the ANB10D maximizes cabinet space. This density allows for more control points per square foot, reducing the overall footprint of the DCS control room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between ANB10D and ANB11D?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ANB10D is for the standard ESB Bus (local or near-distance), while the ANB11D is typically used for the Optical ESB Bus, allowing for much longer distances between the controller and the I\/O node.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I connect the ANB10D-420 to the Field Control Unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NIU connects to the FCU (e.g., AFV30D or AFV10D) using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESB Bus Cables\u003c\/strong\u003e. For a redundant system, these cables must be used in pairs to maintain the duplicated communication path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit include the I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The ANB10D-420\/CU2N\/NDEL is the base chassis and power assembly. You must order specific I\/O modules (e.g.,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI141\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e) separately based on your project's I\/O list.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this unit in a 220V AC environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The suffix \"-4\" indicates a 100-120V AC rating. For 220-240V AC power environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANB10D-2xx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52471919968565,"sku":"ANB10D-420\/CU2N\/NDEL","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AFV10D-S41211_03c771f0-6ed6-484b-ba42-4763397b983a.jpg?v=1774341857","url":"https:\/\/www.5gplc.com\/products\/anb10d-420-cu2n-ndel-yokogawa-duplicated-node-interface-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}