{"product_id":"anb10d-417-cu2n-yokogawa-centum-vp-dual-redundant-esb-bus-node-unit","title":"ANB10D-417\/CU2N | Yokogawa | CENTUM VP Dual-Redundant ESB Bus Node Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-417\/CU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-availability remote I\/O chassis for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control system (DCS). This unit establishes a high-speed, deterministic link between the Field Control Unit (FCU) and I\/O modules via the Extended Serial Backplane (ESB) bus. Designed specifically for mission-critical industrial applications, it utilizes a dual-redundant (active-active) power architecture to eliminate single points of failure. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak performance in demanding refinery, chemical, and power generation environments.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes a specific suffix logic to define the electrical and interface capabilities of the ANB10D series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix\/Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant power supply architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 – 120 V AC input voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDesign Variant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type (Non-Ex) optimized for cabinet integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard ESB Bus interface without internal termination\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-417\/CU2N provides the physical infrastructure for dense I\/O configurations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant ESB bus support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual active-active 100–120 V AC (50\/60 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 200 VA \/ 120 W at maximum load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 slots for Centum VP modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 13 units per AFV30\/AFV40 controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Format:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19-inch rack mount (8U height)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Hardware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eM5 × 4 mounting screws and insulation bushings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Intermediate Nodes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCU2N interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elacks internal termination, making this unit the ideal choice for start or intermediate positions in an ESB bus chain. It allows the communication signal to pass through seamlessly to subsequent nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density I\/O Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis unit hosts up to 8 I\/O modules within a compact 8U footprint. It allows engineers to increase I\/O density within existing control cabinets without the cost and complexity of adding additional Field Control Units (FCUs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive-Active Power Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike passive backup systems, the dual-redundant power supplies share the load actively. If one power path fails, the remaining module instantly assumes the full load, preventing system reset and maintaining process continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Rack Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 19-inch rack-mount design simplifies installation in standard industrial enclosures. The included insulation bushings prevent ground loops and protect sensitive electronics from electromagnetic interference (EMI) often found in heavy industrial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the ANB10D-417\/CU2N as the final node in a bus chain?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGenerally, no. The CU2N connector does not include internal termination. You typically require the CU2T version (with terminator) or a separate external terminator for the final node in the chain to prevent signal reflection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support \"Hot Swapping\" of power supplies?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The active-active redundancy allows you to replace a faulty power module while the system remains operational, ensuring zero downtime for your process loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum number of nodes I can connect to a single controller?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou can connect up to 13 ANB10D units to a single AFV30 or AFV40 controller, allowing for massive I\/O expansion across your facility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit suitable for hazardous (Class 1 Div 2) areas?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis specific model (ANB10D-417) is a basic type (non-Ex). For hazardous area requirements, you must verify the specific protection rating of your enclosure or consult the Yokogawa \"Ex-rated\" hardware catalog.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52763036025141,"sku":"ANB10D-417\/CU2N","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ANB10D-427CU2N_9501b816-7466-41d9-9498-d7c47548d6a2.png?v=1776670003","url":"https:\/\/www.5gplc.com\/products\/anb10d-417-cu2n-yokogawa-centum-vp-dual-redundant-esb-bus-node-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}