{"product_id":"anb10d-223-s2-yokogawa-duplicated-node-interface-unit-niu","title":"ANB10D-223\/S2 | Yokogawa Duplicated Node Interface Unit (NIU)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-223\/S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDuplicated Node Interface Unit (NIU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to expand the I\/O capacity of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField Control Stations (FCS). This unit acts as a high-reliability subrack that houses up to 8 FIO (Field Input\/Output) modules. The \"D\" suffix signifies its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDuplexed (Redundant)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture, ensuring that communication between field sensors and the central controller remains uninterrupted during a component failure. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"S2\" revision\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates a specialized hardware update focused on enhanced ESB bus signal stability and improved resistance to long-term component aging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original Factory Sealed.\u003c\/p\u003e\n\u003ch2\u003ePart Number Breakdown: ANB10D-223\/S2\u003c\/h2\u003e\n\u003cp\u003eYokogawa utilizes a structured suffix code to define the power requirements and mounting style:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eANB10D:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDuplicated Node Interface Unit (for FIO).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant 220-240 V AC Power Supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19-inch Rack-mount type with insulation bushing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic hardware type with specific revision enhancements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/S2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuffix code for improved ESB bus stability and component longevity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe ANB10D-223\/S2 provides a stable electrical environment for high-density I\/O modules.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of I\/O Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 slots (supports Analog, Digital, and Communication FIO modules)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Bus:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eESB Bus (Extended Serial Backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e220-240 V AC, 50\/60 Hz (Dual-redundant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 19-inch rack-mount (with insulation bushing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax 80 VA (at 220-240 V AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstand Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC between power terminals and ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 50°C (Operating)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 10 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMission-Critical Availability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ANB10D-223\/S2 is equipped with dual-redundant power supplies (\u003cstrong\u003ePW482\u003c\/strong\u003e) and supports dual-redundant ESB bus interface modules (\u003cstrong\u003eEC401\u003c\/strong\u003e). This ensures that a failure in one power circuit or communication cable does not result in the loss of 8 I\/O channels, maintaining plant safety and production.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS2 Revision Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"S2\" hardware revision incorporates updated internal circuitry specifically engineered to resist thermal aging. It provides superior signal integrity for the high-speed ESB communication bus, which is critical in large-scale distributed architectures where signal timing is precise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient 220V Power Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned specifically for 220-240V AC environments, this model eliminates the need for external step-down transformers in standard international power grids. The internal power units are optimized for high efficiency and low heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible I\/O Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis NIU allows for the physical distribution of I\/O modules across multiple cabinets. By connecting several ANB10D units via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eESB bus cables, engineers can optimize field wiring runs and reduce copper costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnline Hot-Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRedundant power supplies and bus interface modules can be replaced while the system is live. This capability allows maintenance teams to perform repairs without shutting down the associated control loops, drastically reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between ANB10D and ANB10S?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ANB10D is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDuplicated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion (housing two power supplies and two bus interfaces), while the ANB10S is the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSingle\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion. For critical process loops, the ANB10D is the industry standard for preventing I\/O dropouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I connect the ANB10D-223\/S2 to the Field Control Unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NIU connects to the FCU (e.g., AFV30D or AFV10D) using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESB Bus Cables\u003c\/strong\u003e. These cables must be used in pairs for redundant systems to ensure the duplexed communication paths are fully utilized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit include the I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The ANB10D-223\/S2 is the base chassis and power assembly. Specific I\/O modules like the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI143\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be ordered separately based on your signal point requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this unit in a 110V AC environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This model is specifically rated for 220-240V AC. For 110-120V AC power systems, you should use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANB10D-4xx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52471915249973,"sku":"ANB10D-223\/S2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AFV10D-S412112_698fd283-b4b3-415d-9fc9-5127cbf222cb.jpg?v=1774341331","url":"https:\/\/www.5gplc.com\/products\/anb10d-223-s2-yokogawa-duplicated-node-interface-unit-niu","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}