{"product_id":"amm22m-yokogawa-mv-input-multiplexer-module-for-centum-cs-vp-systems","title":"AMM22M | Yokogawa mV Input Multiplexer Module for CENTUM CS\/VP Systems","description":"\u003ch3\u003eYokogawa AMM22M mV Input Multiplexer Module \u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa \u003cstrong\u003eAMM22M\u003c\/strong\u003e is a high-precision millivolt (mV) input multiplexer module designed for the CENTUM CS and CENTUM VP distributed control systems. It solves the challenge of acquiring accurate low-voltage signals from extensive sensor arrays by consolidating up to 22 analog input channels into a single, compact unit. This module is essential for industrial applications requiring high-density data collection, such as temperature monitoring via thermocouples or strain gauge measurements, ensuring signal integrity and system reliability in complex automation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AMM22M is engineered for high input impedance and exceptional accuracy in low-level signal processing.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eParameter\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003emV Input Multiplexer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eAMM22M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eCENTUM CS, CENTUM VP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e22 Analog Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-100 mV to +100 mV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eAllowable Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-0.5 V to +4.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1 MΩ (E1 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e±40 µV (Microvolts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eBurnout Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSelectable (UP \/ DOWN \/ OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDisconnection Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e≤ 10 seconds response time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eData Update Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e12.7 cm x 2.5 cm x 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Code Interpretation\u003c\/h3\u003e\n\u003cp\u003eFor Yokogawa modules, the suffix codes provide critical information about the hardware revision and interface type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAMM22M\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAMM22-AXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA (Suffix -M):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis suffix typically designates the specific hardware revision or \"Modified\" version.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-M\u003c\/strong\u003e: In the context of the AMM series, this often indicates a specific iteration designed for enhanced performance or compatibility with updated carrier standards (such as the AMN32 or AMN34). It distinguishes the unit from earlier revisions (like the base AMM22) which may have different channel counts or isolation specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: Always verify the suffix on the module label to ensure it matches the engineering specifications for your specific CENTUM system configuration.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation is crucial to maintain the high accuracy (±40 µV) specified for the AMM22M.\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Installation\u003c\/strong\u003e: The AMM22M is designed to be mounted in specific I\/O carrier boxes (such as the AMN series). Slide the module into the designated slot until it locks securely into the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring for Low-Voltage Signals\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e: Because the module handles low-level mV signals, it is highly susceptible to electrical noise. You must use high-quality shielded twisted-pair cables for all connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ground the cable shield at the control cabinet end (single-point grounding) to prevent ground loops, which can introduce significant measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBurnout Configuration\u003c\/strong\u003e: Before commissioning, configure the burnout detection settings (UP, DOWN, or OFF) via the system engineering software. This ensures the system correctly identifies sensor failures (e.g., a broken thermocouple wire).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Resistance Check\u003c\/strong\u003e: Ensure the signal source resistance is within the allowable limit (≤ 1 kΩ) to maintain measurement accuracy. High source resistance can lead to voltage drops and reading errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary application for the AMM22M?\u003c\/strong\u003eA: The AMM22M is primarily used for measuring low-voltage signals, such as those from thermocouples, strain gauges, or other millivolt-output sensors. Its high input resistance (1 MΩ) makes it ideal for these sensitive applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the burnout detection feature work?\u003c\/strong\u003eA: The module can be configured to detect open circuits (sensor breakage). If a disconnection occurs, the module drives the signal upscale (UP) or downscale (DOWN) to alert the operator, depending on the user configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the AMM22M compatible with CENTUM VP?\u003c\/strong\u003eA: Yes, this module is fully compatible with both CENTUM CS and CENTUM VP systems, allowing for seamless integration and upgrades within existing control architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does \"E1 MΩ\" input resistance mean?\u003c\/strong\u003eA: This indicates a very high input impedance (typically 1 Megaohm). High impedance ensures that the module draws minimal current from the signal source, preventing the measurement device from loading the circuit and altering the voltage reading.\u003c\/p\u003e\n\u003ch3\u003eShopify SEO Data\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSEO Title:\u003c\/strong\u003eYokogawa AMM22M mV Multiplexer | CENTUM CS\/VP Module | In Stock\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeta Description:\u003c\/strong\u003eGenuine Yokogawa AMM22M mV Input Multiplexer. 22-Channel High Precision for CENTUM VP\/CS. Brand New, In Stock \u0026amp; Fast Shipping. Order Today.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52522729079093,"sku":"AMM22M","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AMM22M.jpg?v=1775033706","url":"https:\/\/www.5gplc.com\/products\/amm22m-yokogawa-mv-input-multiplexer-module-for-centum-cs-vp-systems","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}