{"product_id":"allen-bradley-micro800-digital-output-plug-in-module-2080-ov4","title":"Allen Bradley Micro800 Digital Output Plug-in Module | 2080-OV4","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 2080-OV4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital output expansion module designed specifically for the Micro800 PLC platform. This plug-in module provides four sinking transistor outputs, allowing for precise control of DC loads without expanding the physical footprint of the controller. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full compatibility with Micro810, Micro820, Micro830, and Micro850 series controllers for high-speed switching applications.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe 2080-OV4 utilizes high-quality transistor switching to manage DC field devices with the following electrical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Sinking Outputs (Sink)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransistor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.8V DC min to 30V DC max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Current (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5A (Steady state); 2A Surge for 2 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Current (Min)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0mA @ 10V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50V Continuous (I\/O to Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Connection Terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2... 2.5 mm² (24... 12 AWG)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Yellow LED Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Space Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe plug-in design eliminates the need for additional DIN rail space. Users insert the module directly into the existing controller bay, maintaining a compact cabinet layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Inrush Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe transistor outputs handle surge currents up to 2A for 2 seconds. This capability allows the module to trigger inductive loads like small solenoid valves or high-brightness LED arrays that exhibit high initial power draw.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour integrated yellow LEDs provide immediate visual confirmation of output status. This feature accelerates onsite troubleshooting by allowing technicians to verify PLC command execution without a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Electrical Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe screw connection terminals support a wide range of wire gauges (up to 12 AWG). This ensures a vibration-resistant physical bond, preventing signal loss in heavy machinery environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Isolation Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 50V continuous isolation protects the internal logic of the Micro800 CPU from field-side electrical noise and surges, extending the operational life of the primary controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 2080-OV4 and the 2080-OB4?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2080-OV4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSinking\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutputs (it switches the negative side of the load), while the 2080-OB4 uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSourcing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutputs (switching the positive side). Verify your field device wiring requirements before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace the 2080-OV4 while the PLC is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways power down the controller before inserting or removing plug-in modules. Hot-swapping may cause electrical damage to the CPU or the 2080-OV4 pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended wire type for the screw terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse solid or stranded copper wire rated at 90 °C (194 °F) or higher. Ensure the wire size falls within the 24–12 AWG range to maintain a secure mechanical grip in the screw terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine original product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee this 2080-OV4 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original Allen Bradley stock in factory-sealed packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52475637137717,"sku":"2080-OV4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/2080-OV4.jpg?v=1774404019","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-micro800-digital-output-plug-in-module-2080-ov4","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}