{"product_id":"allen-bradley-5094-ob32-flex-5000-32-channel-digital-sourcing-output-module","title":"Allen-Bradley 5094-OB32 FLEX 5000 32-Channel Digital Sourcing Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5094-OB32\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-density digital control for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFLEX 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This module features 32 sourcing outputs designed to drive a wide array of field devices including solenoids, motor starters, and indicators within an 18–32V DC range. It operates as a critical node in distributed EtherNet\/IP architectures, offering advanced time-synchronization via CIP Sync. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, ensuring your high-speed automation lines benefit from maximum I\/O density and factory-certified diagnostic capabilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 5094-OB32 utilizes a compact form factor to deliver high-point-count switching:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Sourcing Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18–32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax On-State Voltage Drop\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 36V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Current Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10A Maximum (Total Module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 mA @ 15V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.65 BTU\/hr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCIP Sync (IEEE 1588)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Load, Short Circuit, Overload, Field Power Loss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–60 °C (32–140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-High I\/O Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 32-channel design allows engineers to double the output capacity in the same physical footprint as standard 16-channel modules. This solves the pain point of limited cabinet space and reduces the number of EtherNet\/IP adapters required for high-point-count machines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCIP Sync Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegration with CIP Sync technology enables sub-microsecond synchronization between I\/O modules across the network. This eliminates \"jitter\" in high-speed sorting or packaging applications where timing accuracy directly impacts production throughput.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Per-Point Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module continuously monitors for open loads and short circuits. It reports these faults instantly to the controller and illuminates per-channel LEDs. This granularity allows maintenance teams to identify the exact failed field device without opening junction boxes or manually probing wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimal Voltage Loss:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA maximum on-state voltage drop of only 0.25V DC ensures that field actuators receive nearly the full supply voltage. This improves the performance of sensitive solenoids and relays that might otherwise fail to engage due to high internal resistance in lower-quality modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Hardware Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in fuses and overvoltage protection up to 36V DC shield the internal electronics from field-side surges and wiring errors. This robust design prevents a single field-side short circuit from damaging the entire I\/O rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 5094-OB32 require a separate terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. You must mount the 5094-OB32 onto a 5094-RTB Removable Terminal Block. This design allows you to replace the module without disconnecting any field wiring, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module handle inductive loads like large motor starter coils?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The sourcing outputs handle typical industrial inductive loads. However, for highly inductive devices, ensure your total module current does not exceed the 10A maximum rating to prevent thermal shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does CIP Sync benefit my system compared to standard I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard I\/O relies on network scan times which can vary. CIP Sync provides a synchronized \"time-stamp\" for all I\/O events across the system, ensuring that outputs trigger at the exact same moment regardless of network traffic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of \"Sourcing\" outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSourcing outputs provide positive voltage (VDC) to the load. This is the industry standard for most North American and European control systems, as it ensures the load remains grounded when the output is in the \"Off\" state, enhancing safety.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52800961413429,"sku":"5094-OB32","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5094-OB32.png?v=1777451751","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-5094-ob32-flex-5000-32-channel-digital-sourcing-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}