{"product_id":"allen-bradley-5069-iy4-compact-5000-i-o-universal-analog-input-module","title":"Allen-Bradley 5069-IY4 Compact 5000 I\/O Universal Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 5069-IY4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance universal analog input module within the Compact 5000 I\/O platform. It provides four highly configurable channels that interface directly with voltage, current, RTD, and thermocouple sensors. This versatility allows engineers to standardize on a single module for diverse instrumentation needs across a CompactLogix 5380 or ControlLogix 5580 system. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, featuring factory-applied conformal coating to ensure long-term stability in corrosive industrial atmospheres.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 5069-IY4 utilizes advanced Sigma-Delta conversion technology to deliver precise digital representations of complex analog signals.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal Analog Input (4 Channels)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSigma-Delta Method\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Ranges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-10 to 10V, 0 to 10V, 0 to 5V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Ranges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 20 mA, 4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermocouple\/Millivolt Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-100 to 100 mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResistive Input Ranges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1–500\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e, 2–1000\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e, 4–2000\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e, 8–4000\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes (Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Width:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 Slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Features:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReal-Time Channel Sampling, Onboard Data Alarming\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.31 lbs (0.14 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnified Instrument Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5069-IY4 eliminates the need for multiple specialized modules. A single slot manages a mix of pressure transmitters (4-20mA), temperature probes (RTD\/TC), and position sensors (0-10V), significantly reducing spare parts inventory costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Environmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe factory-sealed conformal coating protects internal circuitry against humidity, salt spray, and chemical contaminants. This feature prevents dendritic growth and premature board failure in harsh processing plants or offshore applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Sigma-Delta conversion method provides superior noise rejection and high-resolution data. This ensures the PLC receives stable values even in electrically noisy environments where high-power motor drives typically interfere with analog signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOnboard Intelligence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module performs data alarming and real-time sampling locally. This offloads computational tasks from the main CPU, allowing the controller to focus on logic execution while the I\/O module monitors threshold breaches and signal health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 5069-IY4 require an external Cold Junction Compensation (CJC) sensor for thermocouples?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module handles cold junction compensation internally when used with the appropriate Removable Terminal Block (RTB). Always ensure the terminal block is correctly seated to maintain thermal equilibrium for accurate temperature readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I configure each channel for a different input type?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can independently program each of the four channels for any supported range (Voltage, Current, RTD, or TC) through the Studio 5000 Logix Designer software without affecting the settings of the other channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the Conformal Coating on this specific model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe coating acts as a non-conductive barrier that shields the module from environmental pollutants. It effectively solves the industrial pain point of \"creeping corrosion,\" which often leads to intermittent signal loss in wastewater treatment or chemical manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Removable Terminal Block (RTB) should I use with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5069-IY4 typically requires the 5069-RTB18-SCREW or 5069-RTB18-SPRING terminal blocks. Note that these RTBs are sold separately and must match the wiring requirements of your specific field instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52588609339701,"sku":"5069-IY4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5069-IY4.jpg?v=1776410682","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-5069-iy4-compact-5000-i-o-universal-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}