{"product_id":"allen-bradley-5069-aentr-compact-5000-i-o-ethernet-ip-adapter","title":"Allen-Bradley 5069-AENTR Compact 5000 I\/O EtherNet\/IP Adapter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5069-AENTR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the high-speed communication bridge for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley Compact 5000 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. This EtherNet\/IP adapter connects distributed I\/O modules to a Logix5000 controller via a standard Ethernet network. It manages data exchange and provides power to the connected I\/O bank, serving as the critical link in modern, decentralized automation architectures. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, ensuring your facility benefits from maximum network throughput and factory-certified stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 5069-AENTR utilizes a high-performance power and thermal architecture to maintain system uptime:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompact 5000 I\/O (Logix 5069)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMOD Power Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 mA at 18-32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMOD Power Inrush\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1750 mA for 70 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. MOD Passthrough\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.78 Amps at 18-32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.5 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29 BTU per Hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRTB Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 to 0.6 Nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.31 kg (0.69 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Capacity Power Passthrough:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module handles up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9.78 Amps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof MOD power passthrough. This allows a single adapter to support a large bank of I\/O modules without requiring additional power injectors, reducing cabinet complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Port Networking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo Ethernet ports support Linear and Device Level Ring (DLR) topologies. DLR functionality ensures the network remains operational even if a single cable breaks, providing high availability for mission-critical processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Thermal Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware dissipates only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e29 BTU per hour\u003c\/strong\u003e, which prevents heat accumulation in high-density control panels. This efficient thermal design allows the module to operate at up to 60°C without derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Wiring Strategy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe adapter uses Category 1 ports for power and Category 2 for signals and Ethernet. This segregation simplifies electrical noise management and helps technicians adhere to strict wiring standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecise Mechanical Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemovable Terminal Blocks (RTB) with a specific torque rating of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 to 0.6 Nm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eguarantee secure electrical connections that withstand industrial vibrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Power Management\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD Power Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect an 18-32V DC source to the MOD power input. Account for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1750 mA inrush current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhen sizing your power supply to prevent startup voltage dips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSnap the open-style enclosure onto a standard 35mm DIN rail. Ensure the module locks securely to maintain a reliable connection to the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded Category 5e (or better) cabling for all Ethernet ports to mitigate electromagnetic interference in heavy industrial zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApply exactly 0.5 to 0.6 Nm of torque to the terminal screws. Under-tightening causes intermittent signals, while over-tightening damages the terminal housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the 5069-AENTR in a Device Level Ring (DLR) topology?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The dual Ethernet ports natively support DLR, providing a fault-tolerant ring network that maintains communication even during a physical link failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this adapter require a separate power supply for the I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 5069-AENTR draws MOD power (Module Power) to run itself and provides passthrough for the rest of the bank. You must also supply SA Power (Sensor\/Actuator Power) to the system to drive the field-side circuits of the I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the high passthrough current rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 9.78A rating allows the adapter to distribute power to a long sequence of I\/O modules. This eliminates the need for 5069-FPD (Field Power Distributor) modules in many configurations, saving rail space and hardware costs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 5069-AENTR compatible with older CompactLogix 1769 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 5069-AENTR exclusively supports the Compact 5000 I\/O platform. It does not interface with 1769 or 1734 POINT I\/O modules due to different physical backplane and communication architectures.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52800688357685,"sku":"1794-DB32","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5069-AENTR.png?v=1777443956","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-5069-aentr-compact-5000-i-o-ethernet-ip-adapter","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}