{"product_id":"allen-bradley-500fl-cod93-nema-size-2-lighting-contactor","title":"Allen-Bradley 500FL-COD93 NEMA Size 2 Lighting Contactor","description":"\u003cp\u003eConfigured for power distribution control in industrial load circuits, the \u003cstrong\u003eAllen-Bradley 500FL-COD93\u003c\/strong\u003e (\u003cstrong\u003e500FL-COD93\u003c\/strong\u003e Contactor) provides direct physical\/electrical execution of circuit switching via a three-pole, top-wired feed-thru architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e500FL-COD93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEMA Size\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e110\/120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3 Main Poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProSoft \/ DIN-Rail Mounting Stability and Electrical Protection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e500FL-COD93\u003c\/strong\u003e contactor assembly is designed for installation within open-type enclosures to ensure adequate thermal dissipation. The top-wired feed-thru configuration facilitates streamlined vertical cabling, reducing mechanical stress on the primary terminals. Users must ensure that the surge voltage protection limits of the control circuit are respected when triggering the 120 VAC coil to prevent back-EMF damage to solid-state control logic. Proper mechanical mounting stability on the backplane is mandatory to prevent vibration-induced contact bounce, which can lead to premature wear of the main power poles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this contactor suitable for applications involving frequent cycling?\u003c\/p\u003e\n\u003cp\u003eA: The contactor is rated for standard industrial duty. For applications requiring extremely high cycle rates, the mechanical fatigue life of the contact structure and spring return assembly must be factored into the preventive maintenance schedule.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 120 VAC coil be driven by a 24 VDC control signal?\u003c\/p\u003e\n\u003cp\u003eA: No. The coil is specifically rated for 110\/120 VAC operation at 50\/60 Hz. Driving the coil with 24 VDC will result in failure to engage the contactor, while exceeding the voltage rating will result in immediate coil burnout. An intermediate interposing relay is required to bridge the voltage differential.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the contactor housing and main poles for debris or shipping damage prior to panel installation.\u003c\/li\u003e\n\u003cli\u003eSecure the open-type contactor to the mounting surface using specified hardware, ensuring the device is level to maintain proper mechanical orientation for the internal armature.\u003c\/li\u003e\n\u003cli\u003eTerminate primary power lines to the top-side feed-thru terminals; ensure all connections are torqued to the manufacturer’s specification to prevent localized heating.\u003c\/li\u003e\n\u003cli\u003eVerify that the control circuit wire gauge is sufficient for the 120 VAC coil current draw and is routed away from high-voltage power lines.\u003c\/li\u003e\n\u003cli\u003eConfirm that the contactor moves freely when manually depressed; ensure no wiring binds or interferes with the armature mechanism.\u003c\/li\u003e\n\u003cli\u003eEnergize the coil circuit to perform a continuity test across the main power poles, verifying a positive and audible \"snap\" during engagement.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52927460147509,"sku":"500FL-COD93","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/500FL-COD93.png?v=1779861957","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-500fl-cod93-nema-size-2-lighting-contactor","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}