{"product_id":"allen-bradley-2198-c4075-ers-kinetix-5300-single-axis-ethernet-ip-servo-drive","title":"Allen-Bradley 2198-C4075-ERS Kinetix 5300 Single-Axis EtherNet\/IP Servo Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e2198-C4075-ERS\u003c\/strong\u003e operates as a high-performance, single-axis AC servo drive within the Kinetix 5300 motion control platform. This 7.5 kW power-class drive regulates velocity, torque, and position loops for compatible synchronous servo motors and induction motors across native EtherNet\/IP networks.\u003c\/p\u003e\n\u003cp\u003eBy integrating hardware-based safety functions and a high-speed control fabric, this drive coordinates complex motion profiles for packaging lines, material handling systems, and assembly machinery. We supply this motion component exclusively as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed unit\u003c\/strong\u003e, guaranteeing untouched internal power electronics, uncompromised factory firmware calibration, and zero previous system deployment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below logs the precise electrical thresholds, power ratings, and physical capabilities of the servo drive:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance \u0026amp; Industrial Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2198-C4075-ERS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKinetix 5300 Motion System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-Axis EtherNet\/IP Servo Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Power Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMain Input Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V AC, Three-Phase Class\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e27.5 Amperes (RMS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Communication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-Port EtherNet\/IP (Supports DLR topologies)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Safety Feature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardwired Safe Torque Off (STO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimizes Enclosure Space via Zero-Stack Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe physical housing profile supports direct, side-by-side zero-stack mounting inside electrical enclosures. This layout eliminates the traditional airflow gaps between adjacent drives, allowing panel builders to cram multiple 7.5 kW axes into exceptionally narrow, compact control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Safety Architecture with Hardwired STO:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe built-in Safe Torque Off (STO) circuit removes power from the drive's output power transistors without dropping the primary control bus voltage. This hardwired connection removes the need for bulky external three-phase main contactors, cutting hardware costs and enabling rapid machine restarts after a safety curtain trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuppresses Network Communication Failures:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual integrated EtherNet\/IP ports support Device Level Ring (DLR) network topologies. If a physical network cable snaps or unseats during production, the DLR protocol automatically re-routes the motion control commands in microseconds, preventing total system shutdowns and preserving active axis coordination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I run this drive on a single-phase AC incoming power line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 2198-C4075-ERS requires a true three-phase 400V AC input to properly balance the internal DC bus rectification stage at its full 7.5 kW power rating. Attempting to run this specific model on single-phase power triggers an immediate phase-loss fault code and prevents the drive from enabling the axis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific wiring practices protect the motor feedback loop from electromagnetic interference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians must use factory-recommended shielded cables to route the motor power and feedback signals. Separate these motor cables from low-voltage data lines by at least 10 inches inside the wire ducts, and ground the high-coverage cable shields directly to the enclosure's metal backplate using 360-degree grounding clamps to drain off high-frequency PWM switching noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this drive support third-party servo motors, or does it restrict use to Allen-Bradley models?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Kinetix 5300 platform natively recognizes Allen-Bradley VP-Series, MP-Series, and TL-Series servo motors via automatic feedback recognition. However, the software configuration tool also permits manual motor profiling, allowing the 2198-C4075-ERS to control third-party permanent magnet synchronous motors or standard induction motors once you input the exact winding and feedback data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52905095201077,"sku":"2198-C4075-ERS","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/2198-C4075-ERS1.png?v=1779249431","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-2198-c4075-ers-kinetix-5300-single-axis-ethernet-ip-servo-drive","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}