{"product_id":"allen-bradley-2094-se02f-m00-s1-kinetix-6200-sercos-interface-control-module","title":"Allen Bradley 2094-SE02F-M00-S1 Kinetix 6200 SERCOS Interface Control Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 2094-SE02F-M00-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance SERCOS interface control module for the Kinetix 6200 multi-axis servo drive system. This module provides the essential communication link between the Logix 5000 controller and the power module, managing complex motion trajectories via high-speed fiber optic synchronization. It integrates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafe Torque-Off (STO)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeature to ensure operator safety while maintaining system uptime. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, ensuring your motion control system operates with factory-certified precision and safety compliance.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe Kinetix 6200 coding system identifies specific interface and safety configurations:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSegment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e2094\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKinetix Modular Drive Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSERCOS Interface (Serial Real-time Communication System)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e02F\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFiber Optic Port Configuration (Rx\/Tx)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eM00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Control Features\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Safe Torque-Off (STO) Functionality\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 2094-SE02F-M00-S1 operates within the following technical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSercos (Fiber Optic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRx\/Tx Fiber Optic Ports; 1 Ethernet Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Feature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafe Torque-Off (STO) - SIL 2 \/ PLd\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eController Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLogix 5000 Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRail Mount (Integrated into Power Module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 50°C (32°F to 122°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.25 lbs (0.57 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 2094-SE02F-M00-S1 addresses high-speed motion and safety integration challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImmunity to Electrical Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe fiber optic Sercos interface eliminates electromagnetic interference (EMI) issues common in traditional copper-wired motion networks. This ensures jitter-free synchronization between multiple axes, even when cables pass through high-voltage electrical fields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Safety Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe built-in Safe Torque-Off (STO) function removes power from the motor without shutting down the entire drive. This meets SIL 2 and PLd safety standards, allowing operators to perform maintenance or clear jams safely without the long restart times associated with total power cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular \"Slide-In\" Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe control module mounts directly onto the front of a 2094 power module. This modularity allows for rapid hardware upgrades or replacements without disturbing the high-voltage power wiring, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated Ethernet port facilitates direct access to drive diagnostics and configuration tools. This allows engineers to troubleshoot motion profiles and monitor drive health in real-time through the Logix 5000 environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate power module to function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 2094-SE02F-M00-S1 is a control header. You must install it onto a compatible Kinetix 6000 or 6200 power module (such as a 2094-BMP5-M) to create a functional servo axis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify if my fiber optic cables are compatible?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module utilizes standard Rx and Tx fiber optic ports. Ensure you use high-quality plastic (POF) or HCS fiber optic cables with the correct numeric aperture to maintain signal integrity over the Sercos ring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a standard 2094-SE02F-M00 with this -S1 version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the -S1 version adds the Safe Torque-Off safety functionality. However, you must update your safety circuit wiring to utilize the STO inputs on the module to comply with local safety regulations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit factory-sealed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery 2094-SE02F-M00-S1 we ship remains in its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory packaging. Each unit features the authentic Rockwell Automation serial number and intact tamper-evident seals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52793200410933,"sku":"2094-SE02F-M00-S1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/2094-SE02F-M00-S1.png?v=1777357642","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-2094-se02f-m00-s1-kinetix-6200-sercos-interface-control-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}