{"product_id":"allen-bradley-1785-ka-plc-5-communication-adapter-module","title":"Allen-Bradley 1785-KA PLC-5 Communication Adapter Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1785-KA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a communication adapter module designed to interface PLC-5 family controllers on Data Highway Plus networks with nodes on the Allen-Bradley Data Highway. It ensures reliable data transmission while providing diagnostic support for troubleshooting and system monitoring.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \u0026amp; Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1785-KA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1785-KA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 V DC, current draw 1.2 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne connector for Data Highway Plus, one connector for Data Highway\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmission Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e57.6 kbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95%, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with Bulletin 1771 I\/O chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables communication between PLC-5 controllers and Allen-Bradley Data Highway nodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLED indicators provide status and fault information for simplified troubleshooting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for reliable operation in industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFits directly into standard 1771 I\/O chassis for fast installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting PLC-5 controllers on Data Highway Plus networks to Data Highway devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring and troubleshooting communication across multiple network nodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial control systems requiring reliable data exchange and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What network types does the 1785-KA support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt connects PLC-5 controllers on Data Highway Plus to nodes on the Allen-Bradley Data Highway.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the transmission speed?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module operates at a transmission rate of 57.6 kbps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be installed in a standard I\/O chassis?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it mounts easily in a Bulletin 1771 I\/O chassis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it provide status indicators for troubleshooting?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, built-in LEDs indicate operational status and faults for easy monitoring.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52240486498613,"sku":"1785-KA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1785-KA.jpg?v=1768901831","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-1785-ka-plc-5-communication-adapter-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}