{"product_id":"allen-bradley-1756-in16-controllogix-digital-ac-input-module","title":"Allen Bradley 1756-IN16 ControlLogix Digital AC Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1756-IN16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density discrete input interface for the ControlLogix platform. This module monitors and converts 24V AC signals from field devices—such as limit switches, pushbuttons, and proximity sensors—into logic levels usable by the controller. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Factory Original\u003c\/strong\u003e, ensuring peak electronic integrity and long-term stability in your automation rack.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1756-IN16 utilizes a robust circuit design to handle industrial AC voltage fluctuations:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Individually Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10V to 30V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current (5.1V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current (24V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation (Max)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.1 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.70 lbs (0.32 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroad Voltage Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module accommodates an input range of 10V to 30V AC. This flexibility allows the hardware to function reliably despite line voltage drops or fluctuations common in large-scale industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Noise Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1756-IN16 incorporates onboard hardware filtering to reject high-frequency electrical noise. This prevents \"nuisance\" signals and false triggering caused by electromagnetic interference (EMI) from nearby motor starters or variable frequency drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis-Based Diagnostic Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes the ControlLogix producer\/consumer technology to report point-level status and fault data. This allows engineers to identify wiring issues or signal loss directly through the Studio 5000 environment without manual probing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis 16-point module optimizes space within the I\/O rack. It utilizes a removable terminal block (RTB), which allows maintenance teams to replace the module without disconnecting individual field wires, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this 1756-IN16 unit 100% Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee this product is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand arrives in its original factory packaging. It has never been installed or used in a production environment, ensuring full lifespan for its internal optical isolators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require a specific Removable Terminal Block (RTB)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1756-IN16 requires either the 1756-TBNH or 1756-TBSH terminal block. You must order these separately as they do not come standard with the module itself.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for DC input signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1756-IN16 is specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAC voltage\u003c\/strong\u003e. Using DC signals may result in improper state detection or damage to the internal bridge rectification circuitry. For DC applications, please refer to the 1756-IB16 or 1756-IV16.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle signal debounce?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features programmable input filter times. You can configure these settings in the controller software to match the mechanical characteristics of your field devices, effectively eliminating contact bounce issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52863169855797,"sku":"1756-IN16","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1756-IN161.png?v=1778472053","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-1756-in16-controllogix-digital-ac-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}