{"product_id":"allen-bradley-1756-if16ihk-controllogix-16-channel-hart-isolated-analog-input-module","title":"Allen-Bradley 1756-IF16IHK ControlLogix 16-Channel HART Isolated Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IF16IHK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density, high-performance analog interface within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystem. This module provides 16 individually isolated channels that support both standard 4-20mA signals and advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART (Highway Addressable Remote Transducer)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edigital communication. The \"K\" suffix designates a conformal coating, protecting the internal circuitry from corrosive industrial atmospheres. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory stock, enabling seamless integration of smart field devices into your ControlLogix chassis for enhanced diagnostic visibility.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix (1756)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Isolated HART Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Individually Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–20 mA, 4–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 to 21 Bits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Ohms (\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e 5 Ohms)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e225 mA @ 5.1V DC; 200 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.30 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSlot Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 (Standard Chassis Slot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel-to-Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1756-IF16IHK provides 250V continuous isolation between every input. This electrical barrier prevents ground loops and stops field-side transients on one loop from affecting adjacent channels, ensuring signal integrity in complex electrical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated HART Data Access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module acts as a HART bridge, allowing the ControlLogix controller to extract secondary variables and device health diagnostics directly from smart transmitters. Engineers monitor device status and calibration data in real-time without needing external handheld communicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Resolution Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a selectable resolution of 16 to 21 bits, the module captures minute process fluctuations. This high granularity proves essential for precision flow monitoring, chemical dosing, and custody transfer applications where every microampere represents critical data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConformal Coating for Harsh Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"K\" version includes a protective layer that resists moisture, fungus, and chemical contaminants. This ensures long-term reliability in wastewater treatment plants, refineries, and paper mills where airborne corrosives typically degrade standard electronic hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Overvoltage Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal circuitry shields the module against accidental wiring errors or surges up to 28.8V DC. This protection prevents costly module failure during commissioning or field maintenance errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1756-IF16IHK require a specific Removable Terminal Block (RTB)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Due to the 16-channel isolated density, this module requires the 36-pin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBCH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-TBSH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal block. We recommend verifying the RTB compatibility to ensure correct field wiring alignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for non-HART analog sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The module functions as a high-precision standard isolated analog input card. You can disable HART functionality in the Studio 5000 configuration for channels that only require 4-20mA signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"H\" in the part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"H\" signifies HART communication capability. This allows the module to communicate with smart devices to retrieve manufacturer IDs, device tags, and diagnostic information alongside the primary analog signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine, factory-sealed unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. It ships in its original Allen-Bradley factory packaging with intact security seals, ensuring the conformal coating and internal electronics remain in pristine condition from the production line to your facility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52532279902517,"sku":"1756-IF16IHK","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1756-IF16IHK.jpg?v=1775205957","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-1756-if16ihk-controllogix-16-channel-hart-isolated-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}