{"product_id":"allen-bradley-1606-xlsred80-bulletin-1606-power-distribution-redundancy-module","title":"Allen-Bradley 1606-XLSRED80 Bulletin 1606 Power Distribution Redundancy Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1783-MMX16T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides essential fault-tolerant capabilities for critical 24-28V DC power systems. This Bulletin 1606 redundancy module decouples two power supplies, preventing a single failed unit from pulling down the entire DC control bus. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your automated systems maintain continuous uptime even during power supply failures or maintenance intervals. It supports a massive 1920 Watts of throughput, making it the standard for high-current industrial applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24–28V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVin - 0.7V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1920 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent (Single Input)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent (Dual Input)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBulletin 1606 XLS Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail Mountable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.00 lbs (0.45 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLossless Decoupling Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1606-XLSRED80 utilizes high-performance diode or MOSFET technology to isolate parallel power supplies. This isolation prevents a short circuit on the input side of one power supply from affecting the output bus, ensuring the secondary supply takes over the load instantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMassive Current Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module manages up to 80 Amps in dual-input mode. It accommodates large-scale I\/O racks and high-power motor drives within a compact 1.00 lb housing, eliminating the need for bulky, custom-built diode arrays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module simplifies diagnostic routines by providing clear separation between power sources. Maintenance teams can hot-swap a failed power supply unit without shutting down the controller or the manufacturing line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePassive Cooling Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware design maximizes heat dissipation without internal fans. This enhances reliability in dusty or oil-mist environments common in automotive and heavy machining industries, where fan-based cooling often leads to premature component failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the voltage drop across this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1606-XLSRED80 incurs a nominal voltage drop of approximately 0.7V DC between the input and output. To maintain exactly 24V DC at your load, adjust the output voltage of your primary power supplies to 24.7V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to combine two different power supply brands?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided both power supplies operate within the 24-28V DC range and share a common ground. However, for optimal load balancing and thermal stability, we recommend using matched Allen-Bradley 1606 series power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit ship in original factory packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We ship each 1606-XLSRED80 as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware in its factory-sealed box. This guarantees the integrity of the internal components and ensures the product meets all original manufacturer performance specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I wire this for maximum redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect the output of \"Power Supply A\" to Input 1 and \"Power Supply B\" to Input 2. Join the common output terminal to your load. This configuration allows the 1606-XLSRED80 to pull the full 80A current capacity or provide a 1+1 redundant failover for 40A loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52774242287925,"sku":"1606-XLSRED80","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1606-XLSRED80.jpg?v=1776824635","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-1606-xlsred80-bulletin-1606-power-distribution-redundancy-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}