{"product_id":"allen-bradley-1585-c8cb-s100-industrial-ethernet-media-cable-spool","title":"Allen-Bradley 1585-C8CB-S100 Industrial Ethernet Media Cable Spool","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1585-C8CB-S100 functions as a high-integrity industrial Ethernet raw media spool engineered for demanding plant-floor data networks. This 100-meter bulk cable roll allows site technicians to pull custom-length network drops directly between programmable automation controllers, remote I\/O chassis, and industrial switches.\u003c\/p\u003e\n\u003cp\u003eThe bare conductor profile supports custom field termination using rugged RJ45 or M12 connectors to match precise machine geometries. We distribute this network media exclusively as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-packaged spool\u003c\/strong\u003e, which guarantees untouched copper strands, a pristine continuous exterior insulation jacket, and uncompromised internal shielding layers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below logs the mechanical properties, shielding metrics, and data transmission parameters of the 1585-C8CB-S100 cable spool:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance \u0026amp; Industrial Network Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1585-C8CB-S100 (Alt: 1585C8CBS100)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Cable and Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeavy-Duty Industrial Ethernet Networks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Meters (Approximately 328 Feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Conductors configured in 4 Twisted Pairs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Gauge Sizing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26 AWG Stranded Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor Core Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Copper Network Core\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eJacket Material \u0026amp; Color\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Grade PVC \/ Teal Finish\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShielding Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Layer: Aluminum Foil Layer \u0026amp; Braided Mesh Shield\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Bandwidth Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100BASE-TX (Fast Ethernet Protocols)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Mbit\/s Data Velocity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Connector Installed \/ Bare Flying Leads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGross Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.00 lbs (5.90 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeflects Severe Motor-Induced EMI via Dual-Layer Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable assembly combines a solid aluminum foil wrap with a tightly woven tinned-copper braided mesh shield. This dual-layer shield blocks high-frequency electromagnetic noise and radio frequency interference (RFI) generated by adjacent variable frequency drives (VFDs) and high-voltage motor starters, stopping data packet degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstands Corrosive Environmental Abuse via Heavy PVC Jacket:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ruggedized, high-durability teal PVC jacket resists breakdown from splashing machine oils, vaporized coolants, abrasive dust, and ambient humidity. This outer skin enables long-term deployment inside oily machining centers and automated automotive assembly bays without cracking or peeling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Routing through Tight Enclosure Conduits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe flexible 26 AWG stranded copper configuration bends easily around sharp panel corners and tight terminal block spaces. The stranded core prevents wire fatigue and internal conductor breakage when pulling the cable through narrow, winding wire tracks or dynamic machine hinges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat industrial connectors fit this raw 1585-C8CB-S100 flying lead cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians plug this raw media into standard industrial-grade RJ45 crimp connectors or heavy-duty M12 D-coded field-attachable insulation displacement connectors (IDCs). Because the cable uses a 26 AWG stranded wire format, you must verify that your selected field-installable connector specifically accepts 26 AWG conductor sizing to guarantee a tight, gas-proof termination pin connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this 100BASE-TX cable support modern Gigabit Ethernet automation hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1585-C8CB-S100 features a 4-pair design optimized specifically for 100BASE-TX Fast Ethernet running at 100 Mbit\/s. While a 4-pair layout physically contains enough conductors for Gigabit networks, the internal electrical twist pitch and 26 AWG gauge parameters optimize for 100 Mbps transmission limits; using it for true Gigabit (1000BASE-T) transfers over long spans may cause signal attenuation and packet retries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions prevent shield termination failures during the installation process?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen stripping the outer teal PVC jacket back to expose the flying leads, technicians must avoid slicing the internal braided wire matrix. Unravel the braid, gather the shield strands together, and crimp or solder them directly to the metallic shroud of your shielded RJ45 plug or M12 backshell to maintain 360-degree grounding continuity from chassis to chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52906260529461,"sku":"1585-C8CB-S100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1585-C8CB-S100.png?v=1779258825","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-1585-c8cb-s100-industrial-ethernet-media-cable-spool","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}