{"product_id":"allen-bradley-150-tc1-smc-50-iec-terminal-cover","title":"Allen-Bradley 150-TC1 SMC-50 IEC Terminal Cover","description":"\u003cp\u003eConfigured for touch-safe operation in industrial motor control circuits, the \u003cstrong\u003eAllen-Bradley 150-TC1\u003c\/strong\u003e (\u003cstrong\u003e150-TC1\u003c\/strong\u003e Terminal Cover) provides direct physical execution of dead-front protection for SMC-50 soft starter line or load power terminations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e150-TC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.78 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot Applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Compatibility\u003c\/td\u003e\n\u003ctd\u003e108 A to 135 A range starters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 Dead Front\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e150-TC1\u003c\/strong\u003e is engineered to maintain physical isolation of high-current power stages within SMC-50 configurations. While this is a passive accessory, its installation is necessary to meet safety requirements for electrical panels that integrate I\/O density scaling and communications. By providing dead-front protection, the cover prevents accidental contact with live power terminals, allowing for safer routine maintenance and inspection of nearby controllers or communication modules that interface with Profinet or EtherNet\/IP deterministic networks. This ensures that the overall control cabinet remains compliant with safety standards regarding energized conductor exposure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this terminal cover interchangeable between line and load sides?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 150-TC1 design is symmetrical and can be used to provide dead-front protection for either the line-side or load-side power terminations on compatible SMC-50 starters.\u003c\/p\u003e\n\u003cp\u003eQ: Does the installation of this cover restrict wire access or terminal torque requirements?\u003c\/p\u003e\n\u003cp\u003eA: No. The cover is designed to provide safety protection while allowing access for proper conductor termination. Ensure all torque specifications for the power terminals are met before snapping the cover into its final protective position.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that all power to the soft starter is locked out and tagged out prior to installation.\u003c\/li\u003e\n\u003cli\u003eAlign the terminal cover with the mounting features on the SMC-50 device housing.\u003c\/li\u003e\n\u003cli\u003eVerify that the cover fully seats over the terminal block assembly, ensuring a snap-fit that prevents accidental removal.\u003c\/li\u003e\n\u003cli\u003eCheck that no power cabling is pinched or stressed by the cover during installation, as this can compromise the mechanical integrity of the protection.\u003c\/li\u003e\n\u003cli\u003eIf removing the cover for maintenance, use a flat-head screwdriver if necessary to gently release the locking tabs without deforming the plastic housing.\u003c\/li\u003e\n\u003cli\u003ePeriodically inspect the cover for cracks or thermal damage, especially if the surrounding environment experiences significant temperature fluctuations or vibration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52927707349301,"sku":"150-TC1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/150-TC1.png?v=1779868727","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-150-tc1-smc-50-iec-terminal-cover","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}