{"product_id":"allen-bradley-1492-concab005y-1771-to-1756-digital-i-o-conversion-cable","title":"Allen-Bradley 1492-CONCAB005Y 1771-to-1756 Digital I\/O Conversion Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1492-CONCAB005Y\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a critical link for high-voltage digital I\/O modernization. This 0.5-meter pre-wired cable assembly facilitates the seamless transition from legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLC-5 (1771 series)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules to modern\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControlLogix (1756 series)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. It eliminates the need to manually terminate hundreds of wires during a system upgrade by bridging existing field wiring to the new Logix architecture. We supply this cable as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, ensuring factory-crimped integrity and precise electrical matching for 120\/240V AC digital circuits.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1492-CONCAB005Y adheres to rigorous electrical standards for industrial AC signal conversion:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1492-CONCAB005Y\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Meter (1.64 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150–240V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Capacity (Per Pin)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Capacity (Per Module)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Amps (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1771 to 1756 Digital I\/O Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePre-wired Harness\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.18 lbs (0.08 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Manual Rewiring Errors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis pre-wired harness maps the legacy 1771 pinouts directly to the 1756 module format. This internal mapping removes the risk of cross-wiring, which often occurs during manual terminal block migrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDrastic Reduction in Downtime:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTraditional I\/O migration can take days of manual labor. The 1492-CONCAB005Y allows maintenance teams to complete hardware cutovers in minutes by utilizing plug-and-play connectivity between conversion modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned specifically for 150-240V AC signals, the cable utilizes insulation and conductors rated for high-voltage digital switching. It maintains clear signal logic without the risk of insulation breakdown or arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for High-Density Panels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 0.5-meter length provides sufficient slack for routing within the conversion chassis while preventing excessive cable clutter. This compact design ensures that cabinet doors close properly and airflow remains unobstructed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-Duty Load Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a 2A per-pin rating and a total module capacity of 12A, this cable easily handles high-current AC outputs, such as those used for large motor starters, solenoids, and high-wattage indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure you pair this cable with the correct 1492 conversion mounting assembly and the designated 1756 digital I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Seating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlign the cable connectors with the conversion base. Press firmly until the connector seats fully to prevent intermittent \"open-circuit\" faults during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStrain Relief:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the cable through the designated chassis channels. Avoid sharp bends that exceed the minimum bend radius of the PVC jacket to prevent internal conductor fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfirm that the field-side voltage matches the 150-240V AC rating of the 1492-CONCAB005Y before energizing the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this cable for 24V DC digital I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 1492-CONCAB005Y is specifically rated and wired for 150-240V AC signals. Using this cable for DC signals may result in improper logic mapping or electrical interference; always use the DC-specific version of the 1492 conversion cables for low-voltage circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this cable include the conversion mounting plate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This part number refers only to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epre-wired cable harness\u003c\/strong\u003e. You must purchase the 1492 conversion base and the ControlLogix chassis mounting assembly separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many cables do I need for a single I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypically, one 1492-CONCAB005Y cable services one I\/O module migration. However, you should consult your specific migration wiring diagram, as some high-density modules may require specific harness configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 0.5-meter length adjustable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The cable comes factory-terminated at a fixed length of 0.5 meters to ensure calibrated resistance and signal timing. If your application requires a different length, please consult the 1492-CONCAB series for alternative options.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52800825098549,"sku":"1492-CONCAB005Y","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1492-CONCAB005Y.png?v=1777448312","url":"https:\/\/www.5gplc.com\/products\/allen-bradley-1492-concab005y-1771-to-1756-digital-i-o-conversion-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}