{"product_id":"aip444-s1-centum-dcs-analog-input-module-yokogawa","title":"AIP444-S1 | CENTUM DCS Analog Input Module | YOKOGAWA","description":"\u003ch2\u003e\u003cspan class=\"qwen-markdown-text\"\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Yokogawa AIP444-S1 is a high-density, multi-function analog input module engineered for the CENTUM VP and CS 3000 Distributed Control Systems (DCS). In complex process environments where temperature, pressure, and level variables must be monitored with extreme precision, this module solves the challenge of signal diversity by accepting Thermocouple (TC), Resistance Temperature Detector (RTD), and DC Voltage inputs on a single card. Featuring 8 fully isolated channels, the AIP444-S1 eliminates ground loop errors and ensures data integrity even in electrically noisy industrial settings. Its compact design maximizes cabinet space efficiency while delivering the reliability required for continuous operation in power generation, petrochemical refining, and pharmaceutical manufacturing.\u003c\/p\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"qwen-markdown-table\"\u003e\n\u003cthead class=\"qwen-markdown-table-thead\"\u003e\n\u003ctr class=\"qwen-markdown-table-thead-tr firstRow\"\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eParameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"qwen-markdown-table-tbody\"\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eModel Number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eAIP444\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eStyle Code\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eS1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eManufacturer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eModule Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eMulti-Input Analog Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSystem Compatibility\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eCENTUM VP, CENTUM CS 3000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eChannel Count\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e8 Channels (Isolated)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eInput Signal Types\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThermocouple (TC), RTD, DC Voltage (mV\/V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eInput Isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eChannel-to-Channel and Channel-to-Bus Isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eConversion Accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e±0.1% of span (Typical, dependent on sensor type)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCold Junction Compensation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eAutomatic internal compensation for TC inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePower Consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eLow power design (Optimized for high-density nodes)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eDimensions (H×W×D)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e130 mm × 30 mm × 100 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eUnit Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eApprox. 0.25 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e-20°C to 70°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eMounting Style\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eBackplane Mount (CENTUM VP Node)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eHot-Swapping\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eSupported (Non-disruptive replacement)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eDiagnostic Features\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eWire break detection, Over-range\/Under-range alarms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eModel Code Decomposition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eYokogawa's CENTUM VP I\/O modules utilize a strict naming convention where the base part number defines the electrical function, and the \"Style\" suffix indicates the hardware revision, component sourcing, and firmware compatibility. Using the correct style is critical for system recognition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePart Number: AIP444-S1\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eAI\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Identifies the hardware series within the Yokogawa CENTUM VP family, specifically for standard I\/O and interface units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eP\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Denotes the \"Processor\" or \"Interface\" functional category. This indicates a smart I\/O module with onboard microprocessors responsible for signal linearization, cold junction compensation (for TCs), and digital filtering.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e444\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: The unique designator for the 8-channel Multi-Input Analog Unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe first \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e\"4\"\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e typically correlates to Analog Input types capable of handling low-level signals (mV, TC, RTD).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e\"44\"\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e sequence specifies the 8-channel density and the versatility to accept multiple sensor types (TC\/RTD\/Voltage) via software configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e-S1 (Style 1)\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: This suffix is mandatory and indicates the specific hardware revision level.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eS1\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Represents the initial or primary production revision of the AIP444. It defines the specific analog-to-digital converter (ADC) architecture, isolation barrier components, and firmware map compatible with CENTUM VP R3.x and later stations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCompatibility Logic\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Substituting an S1 module with a different style (e.g., S2, S3) without verifying backplane compatibility may result in the station failing to recognize the card or reporting hardware errors. The \"S1\" ensures exact pin-out alignment and voltage tolerance matching the original system design.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eInstallation Recommendations and Wiring Guidelines\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eProper installation of the AIP444-S1 is essential to maintain the accuracy of low-level temperature and voltage signals and to leverage its isolation features.\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSoftware Configuration First\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Before wiring, use the CENTUM VP engineering tool (Vx-Toolset) to configure each of the 8 channels for the specific sensor type (e.g., Type K Thermocouple, Pt100 RTD, or 1-5V). The module does not auto-detect sensor types; incorrect software settings will yield erroneous readings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCable Selection\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eThermocouples\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Use compensated extension wires matched to the thermocouple type (e.g., KX for Type K) to prevent measurement errors at the terminal block.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eRTDs\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Use 3-wire or 4-wire shielded cables to compensate for lead resistance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eShielding\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: All signal cables must be shielded twisted pair. Ground the shield at the control room end only (single-point grounding) to utilize the module's channel isolation effectively and prevent ground loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eTerminal Wiring\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Connect sensors to the front terminal block. Ensure tight connections (torque approx. 0.5 N·m) to prevent contact resistance, which is critical for low-resistance RTD measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCold Junction Reference\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: The AIP444 measures internal temperature for Cold Junction Compensation (CJC). Ensure the module is not installed directly adjacent to high-heat sources (like power supplies) within the rack, as localized heating can affect TC accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eNoise Mitigation\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Keep analog signal wiring separate from high-voltage AC lines and variable frequency drive (VFD) outputs. Maintain a minimum separation of 20 cm to prevent electromagnetic interference (EMI) from corrupting low-level mV signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eHot-Swap Procedure\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: While the module supports hot-swapping, it is best practice to force the associated tags to \"Hold\" or \"Manual\" mode in the operator station before removal to prevent process upsets during the brief communication interruption.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eFrequently Asked Questions (FAQ)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Can I mix different sensor types on the same AIP444-S1 module?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: Yes. One of the key advantages of the AIP444-S1 is its flexibility. You can configure Channel 1 for a Type J Thermocouple, Channel 2 for a Pt100 RTD, and Channel 3 for a 0-10V signal simultaneously. Each channel is configured independently via the Vx-Toolset software.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Does this module support 2-wire RTDs?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: Yes, the AIP444-S1 supports 2-wire, 3-wire, and 4-wire RTD configurations. However, for highest accuracy, 3-wire or 4-wire connections are recommended to eliminate lead wire resistance errors. The software must be set to match the physical wiring scheme.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: What happens if a thermocouple wire breaks?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The AIP444-S1 includes built-in burnout detection. If a wire break occurs, the module detects the open circuit and drives the input value to a predefined \"Upscale\" or \"Downscale\" limit (configurable in software), triggering an immediate alarm in the DCS to alert operators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Is the AIP444-S1 compatible with older CENTUM CS 1000 systems?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The AIP444 series is primarily designed for CENTUM VP and CS 3000 architectures. While some backward compatibility exists depending on the node type, it is not natively supported in legacy CS 1000 slots without specific adapter nodes or firmware upgrades. Always verify compatibility with your specific FCS model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Do you supply this module as new or refurbished?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: We supply 100% brand-new, original factory-sealed Yokogawa AIP444-S1 modules. We do not sell refurbished or pulled units for critical control applications to ensure maximum reliability and warranty coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: What is the lead time for shipping?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: We maintain stock of the AIP444-S1 for immediate dispatch. Orders are typically processed and shipped via DHL\/FedEx within 24 to 72 hours, with global delivery usually achieved within 3-5 business days.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52522167894325,"sku":"AIP444 S1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AIP444S1.png?v=1775027634","url":"https:\/\/www.5gplc.com\/products\/aip444-s1-centum-dcs-analog-input-module-yokogawa","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}