{"product_id":"adv551-p63-d5a00-yokogawa-centum-vp-digital-output-module","title":"ADV551-P63\/D5A00 | Yokogawa CENTUM VP Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV551-P63\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital output interface for the CENTUM VP control system. This 32-channel module drives field loads using a current sink format, supporting both standard status switching and sophisticated pulse width\/time-proportional output functions. Engineered for maximum survivability, it features specialized conformal coating for corrosive environments. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full compliance with factory specifications and industrial safety standards.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe ADV551 series employs specific suffix logic to tailor the module to environmental and functional requirements:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eADV551:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output Module (32-channel, 24 V DC, Isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrates pulse width output and time-proportional output functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e6:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes integrated status display (Non-explosion protection version)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdds ISA Standard G3 corrosion resistance and extended temperature rating (-20 to 70 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/D5A00:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATD5A-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKS Cable Interface Adapter for 32-channel digital connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following parameters define the operational limits and performance of the ADV551-P63\/D5A00:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels, Isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Sink\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Applied Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA per channel at 26.4 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kV AC (Signal to System), 500 V AC (Between Commons)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA Standard G3 Conformal Coating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg (Base module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosive Environment Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ISA Standard G3 option protects internal circuitry against harsh atmospheric contaminants like hydrogen sulfide and chlorine. This coating prevents silver and copper corrosion, significantly extending hardware life in chemical processing and wastewater treatment plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Control Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"-P\" functionality enables pulse width and time-proportional outputs. Engineers utilize this feature to control devices requiring variable power delivery or precise duty cycle management without adding specialized pulse modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified High-Density Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/D5A00 interface adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates the use of standard KS cables. This eliminates the need for individual point-to-point wiring of 32 separate channels, reducing cabinet assembly time and minimizing the risk of termination errors in tight spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Thermal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard commercial modules, the \"3\" suffix hardware operates reliably from -20°C to 70°C. This allows for installation in non-climate-controlled field enclosures across diverse geographic locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, you can install or remove the ADV551-P63\/D5A00 within a compatible CENTUM VP I\/O nest while the system is powered, provided you follow standard Yokogawa safety procedures for DCS maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module drive 100mA loads on all 32 channels simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports up to 100 mA per channel at 26.4 V DC. However, always calculate the total power dissipation and cabinet temperature rise to ensure the module remains within its -20°C to 70°C operating window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the G3 coating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt satisfies the ISA S71.04 severity level G3 (Harsh), shielding the module from \"creeping corrosion\" that typically causes short circuits in non-treated industrial electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ATD5A-00 adapter included in the box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The \/D5A00 option code confirms that the module comes pre-equipped with the KS Cable In\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52571496087861,"sku":"ADV551-P63\/D5A00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADV151-P03_903a09a0-dde7-4f78-a397-56627508b9dc.png?v=1776233010","url":"https:\/\/www.5gplc.com\/products\/adv551-p63-d5a00-yokogawa-centum-vp-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}