{"product_id":"adv159-p01-yokogawa-32-channel-digital-input-module-centum-vp","title":"ADV159-P01 | Yokogawa 32-Channel Digital Input Module | CENTUM VP","description":"\u003ch2\u003ePart Number Breakdown: ADV159-P01\u003c\/h2\u003e\n\u003cp\u003eYokogawa utilizes specific alphanumeric codes to denote functionality and hardware revisions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-104\"\u003e\u003c\/span\u003e\u003cstrong\u003eADV159:\u003c\/strong\u003e\u003cspan class=\"citation-104 citation-end-104\"\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module (32-channel, Isolated).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure-clamp terminal connection style.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard type hardware specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUpdated model version for enhanced signal stability and subrack compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe ADV159-P01 provides precise electrical thresholds for reliable binary signal detection.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32, fully isolated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Input Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eON Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eor less\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOFF Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 k$\\Omega$ or more\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShort Circuit Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.25 mA (Minimum)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Input Thresholds:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eON Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e1 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOFF Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.5 to 25 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Contact Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 V DC, 20 mA or more\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStatus Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePushbutton Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e20 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransistor contact (for status feedback)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30 V DC, 100 mA (Inductive\/Resistive loads)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative Pushbutton Logic:\u003c\/strong\u003e\u003cspan class=\"citation-103 citation-end-103\"\u003e\u003cspan\u003e \u003c\/span\u003eThe ADV159-P01 includes dedicated firmware support for pushbutton inputs.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis feature eliminates the need for complex software debouncing or latching logic in the main controller, reducing CPU overhead and simplifying operator interface programming.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual channel isolation prevents electrical noise, ground loops, and cross-channel interference. This architecture ensures that a fault on one field instrument does not propagate to neighboring channels or the internal DCS system bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Signal Versatility:\u003c\/strong\u003e\u003cspan class=\"citation-102 citation-end-102\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module accommodates both dry contact and voltage-level signals.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis versatility allows engineers to mix different types of field instrumentation on a single module, optimizing rack space and reducing the total variety of spare parts required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-101\"\u003e\u003c\/span\u003e\u003cstrong\u003eRapid Response Execution:\u003c\/strong\u003e\u003cspan class=\"citation-101 citation-end-101\"\u003e\u003cspan\u003e \u003c\/span\u003eAn 8 ms response time for status inputs enables real-time tracking of high-speed industrial sequences.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis speed proves vital for sequence-of-events (SOE) recording and safety-critical interlocking where millisecond accuracy prevents equipment downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Transistor Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated transistor contacts drive small relays or signaling LEDs directly. Supporting up to 100 mA at 30 V DC, these outputs provide local feedback loops without requiring additional digital output cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ADV159-P01 require an external power supply for inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides the necessary sensing voltage for dry contact inputs. However, if you utilize the voltage input mode, the field device must provide the 4.5 to 25 V DC signal level to trigger the OFF state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary application for the 20 ms pushbutton response time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 20 ms window acts as a built-in filter to distinguish intentional operator actions from mechanical contact bounce or transient electrical interference, ensuring the DCS registers a clean, singular command.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix inductive and resistive loads on the transistor outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The output contacts handle both load types up to 100 mA. For highly inductive loads, we recommend installing external suppression diodes to protect the transistor junctions from back-EMF spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the P01 version differ from the P00 version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe P01 is a hardware revision that often includes updated internal components for better thermal performance or component longevity. It maintains full backward compatibility with P00 configurations in your CENTUM VP software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52471327981877,"sku":"ADV159-P01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADV159-P00_7674ba48-2e1e-4674-9c74-c3404abb2a60.jpg?v=1774333203","url":"https:\/\/www.5gplc.com\/products\/adv159-p01-yokogawa-32-channel-digital-input-module-centum-vp","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}