{"product_id":"adv159-p00-yokogawa-centum-vp-32-channel-digital-input-module","title":"ADV159-P00 | Yokogawa CENTUM VP | 32-Channel Digital Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV159-P00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density, isolated digital input interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System. This 32-channel module captures discrete signals from field equipment, supporting both standard contact inputs and specialized voltage inputs. With integrated support for pushbutton functions and transistor contact outputs, the ADV159-P00 facilitates complex operator-machine interaction and high-speed status monitoring in mission-critical process environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original Factory Sealed.\u003c\/p\u003e\n\u003ch2\u003ePart Number Breakdown: ADV159-P00\u003c\/h2\u003e\n\u003cp\u003eYokogawa utilizes specific alphanumeric codes to denote functionality and hardware revisions:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eADV159:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module (32-channel, Isolated).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure-clamp terminal connection style.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic type hardware specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard model version for universal subrack compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe ADV159-P00 provides precise electrical thresholds for binary signal detection.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32, fully isolated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Input Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eON Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eor less\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOFF Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 k$\\Omega$ or more\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShort Circuit Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.25 mA (Minimum)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Input Thresholds:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eON Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e1 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOFF Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.5 to 25 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Contact Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 V DC, 20 mA or more\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStatus Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e8 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePushbutton Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\le$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e20 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransistor contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30 V DC, 100 mA (Inductive\/Resistive loads)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative Pushbutton Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ADV159-P00 includes dedicated firmware support for pushbutton inputs. This feature eliminates the need for complex software debouncing or latching logic in the main controller, reducing CPU overhead and simplifying operator interface programming.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual channel isolation prevents electrical noise, ground loops, and cross-channel interference. This architecture ensures that a fault on one field instrument does not propagate to neighboring channels or the internal DCS system bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Signal Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module accommodates both dry contact and voltage-level signals. This versatility allows engineers to mix different types of field instrumentation on a single module, optimizing rack space and reducing the total variety of spare parts required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Response Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn 8 ms response time for status inputs enables real-time tracking of high-speed industrial sequences. This speed proves vital for sequence-of-events (SOE) recording and safety-critical interlocking where millisecond accuracy prevents equipment downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Transistor Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated transistor contacts drive small relays or signaling LEDs directly. Supporting up to 100 mA at 30 V DC, these outputs provide local feedback loops without requiring additional digital output cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ADV159-P00 require an external power supply for inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides the necessary sensing voltage for dry contact inputs. However, if you utilize the voltage input mode, the field device must provide the 4.5 to 25 V DC signal level to trigger the OFF state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary application for the 20 ms pushbutton response time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 20 ms window acts as a built-in filter to distinguish intentional operator actions from mechanical contact bounce or transient electrical interference, ensuring the DCS registers a clean, singular command.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix inductive and resistive loads on the transistor outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The output contacts handle both load types up to 100 mA. For highly inductive loads, we recommend installing external suppression diodes to protect the transistor junctions from back-EMF spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ADV159-P00 hot-swappable in a running system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn a redundant I\/O configuration, you can replace the module without interrupting the process. For non-redundant loops, always follow your facility's safety bypass procedures, as all 32 inputs will lose signal during the swap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52471260807477,"sku":"ADV159-P00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADV159-P00.jpg?v=1774331881","url":"https:\/\/www.5gplc.com\/products\/adv159-p00-yokogawa-centum-vp-32-channel-digital-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}