{"product_id":"adv151-e50-d5a00-yokogawa-centum-vp-32-channel-digital-input-module","title":"ADV151-E50\/D5A00 | Yokogawa CENTUM VP 32-Channel Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV151-E50\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance digital input interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated Production Control System. This module processes 32 isolated digital input channels, converting 24 V DC field signals from switches and relay contacts into system logic. By incorporating Sequence of Events (SOE) capture, the ADV151-E50\/D5A00 provides high-resolution time-stamping for state changes, making it indispensable for fault analysis and precision monitoring in complex industrial processes.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes a modular suffix and option code system to define the functional profile of this I\/O unit:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eADV151\u003c\/strong\u003e: Digital Input Module (32-channel, 24 V DC, Isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-E\u003c\/strong\u003e: Enables SOE (Sequence of Events) capture functionality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5\u003c\/strong\u003e: Standard model with internal status processing (No external LED display)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0\u003c\/strong\u003e: Basic environmental type (Standard coating)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/D5A00\u003c\/strong\u003e: Includes the KS Cable Interface Adapter for 32-channel digital connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-E50\/D5A00 provides the following technical parameters for robust field integration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 isolated digital inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Input Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eON\/OFF (Dry\/Wet contact compatible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSOE Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed time-stamping for event analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust channel-to-system isolation (2 kV AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKS Cable Interface Adapter (D5A00)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Power Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 mA maximum @ 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg (Base module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Root Cause Analysis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SOE capture functionality records signal transitions with millisecond-level precision. This allows engineers to reconstruct the exact sequence of trips or alarms, significantly reducing the time required to diagnose plant upsets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Wiring Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \/D5A00 option provides a dedicated KS Cable Interface Adapter. This design eliminates the need for individual screw terminal wiring at the module faceplate, allowing for a \"plug-and-play\" connection to remote terminal boards via high-density cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Cabinet Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy consolidating 32 isolated channels into a single FIO slot and using the KS interface, this module minimizes cabinet clutter. It solves the pain point of high-density wiring in space-constrained offshore platforms or modular control rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Ground Loops:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComprehensive isolation between field signals and the internal system backplane prevents electrical noise and ground potential differences from affecting the CPU or other I\/O modules. This maintains absolute signal integrity in high-EMI environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ADV151-E50\/D5A00 provided as a brand-new unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply the Yokogawa ADV151-E50\/D5A00 exclusively as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, original product. The module ships in its original factory packaging to ensure authentic quality and performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the \/D5A00 option code?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \/D5A00 code indicates that the module includes a pre-installed interface adapter for KS cables. This allows you to connect the module to a terminal board using a single AKB cable rather than wiring 32 individual points manually.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ADV151-E50\/D5A00 support dual-redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When installed in a compatible redundant node unit, you can pair two ADV151 modules to ensure continuous signal acquisition. This prevents a single module failure from interrupting critical monitoring loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the SOE feature affect the system configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SOE feature requires a compatible controller and software revision within CENTUM VP. Once configured, the module autonomously time-stamps signal changes, relieving the main CPU of high-frequency polling tasks for event recording.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52571556479285,"sku":"ADV151-H50\/D5A00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADV151-P03_3e0ebe53-996b-4e33-9364-2a9bf1274d89.png?v=1776236615","url":"https:\/\/www.5gplc.com\/products\/adv151-e50-d5a00-yokogawa-centum-vp-32-channel-digital-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}