{"product_id":"adm52c-2-yokogawa-centum-cs-3000-contact-output-module","title":"ADM52C-2 | Yokogawa CENTUM CS 3000 Contact Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADM52C-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density contact output interface within the CENTUM Distributed Control System (DCS). This module manages 32 discrete output points, allowing the control system to actuate external devices such as solenoid valves, motor starters, and indicating lamps. It serves as a critical bridge between digital control logic and field-level execution, providing reliable switching performance for industrial automation sequences.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ADM52C-2 utilizes a ruggedized design to handle high-density switching requirements:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eADM52C-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContact Output Module (Discrete Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM4 Screws (Secure termination)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnecting Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKS9 Interface Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Output Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 32-point architecture allows engineers to control an extensive array of field devices from a single slot. This concentration reduces the overall I\/O nest footprint and simplifies cabinet layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Industrial Terminations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM4 screw terminals\u003c\/strong\u003e, which provide superior mechanical retention compared to spring-clamp designs. This ensures electrical contact integrity in high-vibration environments like turbine halls or pumping stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized KS9 Interconnectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS9 connecting cable\u003c\/strong\u003e, the ADM52C-2 streamlines the link between the module and terminal boards. This standardized cabling prevents wiring errors and drastically reduces the time required for system commissioning and cabinet dressing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Load Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal circuitry isolates the control bus from field-side electrical transients. This hardware protection ensures that inductive kickback from solenoids or external relay coils does not compromise the stability of the main DCS processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this Yokogawa ADM52C-2 unit new or refurbished?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eequipment. It arrives in the original factory packaging, ensuring you receive a unit with zero operational wear and full manufacturer reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific cable do I need for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ADM52C-2 requires a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS9 cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor connection to the system interface. Ensure you select the appropriate cable length to reach your terminal block assembly without putting strain on the connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older ADM52 model with the ADM52C-2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ADM52C-2 typically functions as a direct or superior replacement within the CENTUM series. However, always verify your system’s software revision and current terminal board compatibility before hot-swapping hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the unit come with the M4 screws included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module includes the standard M4 screw terminal assembly, allowing for immediate installation and field wiring upon delivery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52542166270261,"sku":"ADM52C-2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADM12C_aec134d3-5168-435a-bbf3-503afc11025c.jpg?v=1775546782","url":"https:\/\/www.5gplc.com\/products\/adm52c-2-yokogawa-centum-cs-3000-contact-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}