{"product_id":"adm11c-yokogawa-centum-cs-3000-contact-input-module","title":"ADM11C | Yokogawa | CENTUM CS 3000 Contact Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADM11C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a versatile digital interface for the CENTUM Distributed Control System (DCS). This module executes precise ON\/OFF detection by monitoring 16 contact input points, with a scalable architecture that allows upgrades to a 32-channel configuration. It processes both dry contact and voltage inputs ranging from 4.5 to 25 V DC, ensuring seamless integration between field sensors and the central controller.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ADM11C utilizes high-speed circuitry and robust electrical isolation to maintain data integrity:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels (Upgradable to 32)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContact Input \/ Voltage Input (4.5 to 25 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time (Status)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time (Pushbutton)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mA at 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKS2 \/ KS3 Connector Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.58 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Condition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable I\/O Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ADM11C offers a unique upgrade path from 16 to 32 channels. This flexibility allows engineers to expand system capacity as plant requirements grow without replacing the existing base hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndependent channel-to-channel isolation eliminates ground loop interference and prevents localized electrical faults from propagating across the entire I\/O nest. This protection significantly enhances the stability of critical process loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe connector-type interface utilizes standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS2 or KS3 cables\u003c\/strong\u003e, replacing traditional point-to-point screw terminal wiring. This design reduces cabinet dressing time and eliminates the risk of human error during commission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Mode Response Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized firmware distinguishes between standard status inputs (8 ms) and pushbutton signals (20 ms). This prevents \"contact chatter\" and ensures the control system only registers intentional physical activations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Yokogawa ADM11C unit provided as new or refurbished?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee the ADM11C as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. Every unit arrives in its original manufacturer’s packaging with factory seals intact, ensuring zero operational wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I upgrade the module from 16 to 32 channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExpansion typically involves configuring the software parameters within the CENTUM engineering station and ensuring the wiring via KS cables supports the higher density. Please consult your specific Yokogawa system manual for firmware compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the connector-type connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe connector-type (ADM11C) allows for \"plug-and-play\" installation. It enables maintenance teams to replace the module in seconds by simply swapping the KS cable, whereas terminal-type modules require disconnecting dozens of individual wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support voltage inputs from third-party sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ADM11C accepts voltage inputs between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4.5 and 25 V DC\u003c\/strong\u003e. This wide range accommodates standard 24V sensors as well as lower-voltage digital electronics commonly found in industrial telemetry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52542189011253,"sku":"ADM11C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADM12C_8be3b0f2-f1e5-45f8-b043-2421f73ea3d5.jpg?v=1775548276","url":"https:\/\/www.5gplc.com\/products\/adm11c-yokogawa-centum-cs-3000-contact-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}