{"product_id":"abb-ypk-114a-3asd399002b20-communication-board","title":"ABB YPK 114A 3ASD399002B20 Communication Board","description":"\u003cp\u003eConfigured for local bus arbitration and industrial communication interfacing in Advant\/Master drive platforms, the \u003cstrong\u003eABB 3ASD399002B20\u003c\/strong\u003e (\u003cstrong\u003eYPK 114A\u003c\/strong\u003e Communications Module) provides direct physical\/electrical execution. The unit functions as a dedicated communication board (DCB-board) responsible for high-speed serial signal conversion, backplane interface management, and deterministic payload forwarding across host controller nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3ASD399002B20 (YPK 114A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16.6 cm x 8.3 cm x 2.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane logic supply (5 VDC \/ 24 VDC bus load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Board \/ DCB-Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Code\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe YPK 114A communication board is designed to interface directly with host drive control racks, managing backplane bus communication velocity to ensure real-time cyclic data exchange. The onboard communication controller executes deterministic serialization and hardware interrupt verification while maintaining strict firmware flash compatibility across matching control software revisions. Integrated signal paths provide channel isolation and packet prioritization, suppressing transmission jitter during continuous industrial operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary operational role of the YPK 114A DCB-board within the system rack? A: The module functions as a dedicated digital communication board, executing serial protocol translation, buffer management, and backplane signaling between connected control modules and peripheral buses.\u003c\/p\u003e\n\u003cp\u003eQ: Can the YPK 114A communication board be hot-swapped during active system operation? A: No, module removal or insertion while the backplane is energized is prohibited; power to the host rack must be isolated prior to physical installation or extraction to prevent bus corruption or hardware damage.\u003c\/p\u003e\n\u003cp\u003eQ: How is power supplied to the YPK 114A circuit board? A: The board receives its operating logic power directly through the multi-pin rack backplane connector upon mechanical engagement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize the host drive system and disconnect all main power supplies before inserting or removing the board from the rack enclosure.\u003c\/li\u003e\n\u003cli\u003eObserve strict electrostatic discharge (ESD) handling procedures, including the use of a grounded wrist strap when handling the unshielded circuit board.\u003c\/li\u003e\n\u003cli\u003eAlign the PCB edges with the rack card guides, sliding the module smoothly until the backplane connectors seat firmly without excessive force.\u003c\/li\u003e\n\u003cli\u003eEnsure all mounting hardware and retaining screws are fully secured to maintain continuous frame ground grounding.\u003c\/li\u003e\n\u003cli\u003eKeep signal wiring separated from high-voltage AC motor cables to prevent electromagnetic coupling into the communication lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53224677966133,"sku":"YPK 114A 3ASD399002B20","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/YPK114A3ASD399002B20.png?v=1785313701","url":"https:\/\/www.5gplc.com\/products\/abb-ypk-114a-3asd399002b20-communication-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}