{"product_id":"abb-xv-c767a-e105-current-measurement-board-3bhb007209r0105","title":"ABB XV C767A E105 Current Measurement Board | 3BHB007209R0105","description":"\u003cp\u003eConfigured for high-precision current sensing in power electronics control networks, the \u003cstrong\u003eABB 3BHB007209R0105\u003c\/strong\u003e (\u003cstrong\u003eXV C767 AE105\u003c\/strong\u003e Current Measurement Board) provides direct electrical execution of current signal acquisition and feedback scaling.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXV C767 AE105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e65 mm x 65 mm x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0-50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 % of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe XV C767 AE105 is engineered for integration within deterministic control platforms. While supporting Modbus RTU, the architecture permits optional Profinet connectivity, allowing for real-time synchronization of current measurement data across the host drive system. Deterministic network performance is maintained through high-speed internal processing, ensuring that the 5 ms response time does not introduce phase shift or latency jitter in control loops. Firmware flash compatibility is supported to align board-level communication protocols with the specific drive configuration, ensuring consistent data packet delivery within the control bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does this board support hot-swapping during active drive operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The board must be completely isolated from the 24 V DC supply and the primary power circuit before removal to prevent electrical damage to the sensor input and communication transceiver.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 0-50 A range configurable via software?\u003c\/p\u003e\n\u003cp\u003eA: The measurement range is fixed at the hardware level. Any deviation in required sensing capacity necessitates a change in the physical hardware module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the board is mounted in a vibration-dampened environment to prevent mechanical stress on the primary sensor connections. Maintain the 65 mm x 65 mm footprint clearance for airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Secure the board using dedicated mounting standoffs connected to the cabinet functional earth. This provides the reference potential for the 0-50 A current measurement circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use twisted-pair shielded cabling for the current sensing inputs. Terminate the shield at the cabinet ground bus, ensuring that signal cables are kept physically separate from high-voltage AC paths to prevent induced interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Verify that the 24 V DC supply is within nominal tolerances prior to energizing. Incorrect voltage levels will lead to measurement drift or total loss of communication with the host controller.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52965735465269,"sku":"XV C767A E105 3BHB007209R0105","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/XVC767AE1053BHB007209R0105.png?v=1780654472","url":"https:\/\/www.5gplc.com\/products\/abb-xv-c767a-e105-current-measurement-board-3bhb007209r0105","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}