{"product_id":"abb-ur600ir-mod-1000-uvisor-flame-detection-probe","title":"ABB UR600IR Mod.1000 Uvisor Flame Detection Probe","description":"\u003cp\u003eThe \u003cstrong\u003eABB UR600IR Mod.1000\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUR600IR\u003c\/strong\u003e Flame Detection Probe, operates as a dedicated hardware component for infrared radiation monitoring and flame quality evaluation within industrial boiler burner management systems (BMS). It monitors infrared flicker frequencies emitted by combustion flames to provide reliable flame disk detection and discrimination.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR600IR Mod.1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eItaly \/ Sweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Uvisor Industrial Probe Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC System Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Spectrum\u003c\/td\u003e\n\u003ctd\u003eInfrared (IR) flicker radiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Applications\u003c\/td\u003e\n\u003ctd\u003eOil, gas, coal, and multi-fuel burner systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Family\u003c\/td\u003e\n\u003ctd\u003eABB Uvisor Flame Monitoring Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; I\/O Isolation Profiles\u003c\/h3\u003e\n\u003cp\u003eThe ABB UR600IR Mod.1000 flame detection probe utilizes optical sensing elements coupled with onboard pre-amplification to optimize signal-to-noise ratios across harsh furnace environments. The unit routes low-frequency flame flicker signals through narrow-band filtering electronics to prevent false discrimination from background thermal radiation and adjacent burner cross-talk. Isolated signal output channels interface with control room control modules (such as Uvisor central units) while integrated internal shielding limits electromagnetic interference along long field cable runs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary spectrum does the UR600IR Mod.1000 utilize for flame detection?\u003c\/p\u003e\n\u003cp\u003eA: The UR600IR Mod.1000 measures infrared (IR) flicker radiation emitted by combustion flames, making it suitable for gas, oil, and pulverized coal burners.\u003c\/p\u003e\n\u003cp\u003eQ: How is thermal protection managed for the probe assembly near high-temperature burner fronts?\u003c\/p\u003e\n\u003cp\u003eA: The housing relies on continuous cooling air purge delivered via the mounting assembly to maintain internal electronics within specified ambient operating temperature limits and keep optical elements clean.\u003c\/p\u003e\n\u003cp\u003eQ: Can the UR600IR probe discriminate between target burner flames and background furnace radiation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, onboard electronic filtering analyzes dynamic flame flicker frequencies to distinguish active combustion from static hot refractory background radiation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the burner management system is safely shut down and local power sources are isolated prior to installation.\u003c\/li\u003e\n\u003cli\u003eMount the sight tube and swivelling head securely to the burner wall, verifying an unobstructed line of sight to the flame target zone.\u003c\/li\u003e\n\u003cli\u003eConnect continuous, clean, dry purge air to the cooling port before exposing the probe to furnace ambient heat.\u003c\/li\u003e\n\u003cli\u003eTerminate signal cables to the rear terminal block using shielded, twisted-pair cabling, anchoring the shield at a single ground point.\u003c\/li\u003e\n\u003cli\u003eTighten all mechanical mounting hardware and threaded connections to ensure minimum 5-thread engagement before re-energizing the flame safety loop.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53412190126389,"sku":"UR600IR","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/UR600IR_99706c56-1c62-40b6-9431-a397626dbe98.png?v=1787819702","url":"https:\/\/www.5gplc.com\/products\/abb-ur600ir-mod-1000-uvisor-flame-detection-probe","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}