{"product_id":"abb-uf-c092-be01-hiee300910r0001-binary-input-module","title":"ABB UF C092 BE01 HIEE300910R0001 Binary Input Module","description":"\u003cp\u003eConfigured for discrete state acquisition and contact monitoring in system subracks, the \u003cstrong\u003eABB UF C092 BE01 HIEE300910R0001\u003c\/strong\u003e (\u003cstrong\u003eUF C092 BE01\u003c\/strong\u003e Binary Input Module) provides direct physical\/electrical execution across ABB control platforms. The module interfaces external dry contacts, limit switches, and binary sensors with the central processing unit via the subrack backplane logic bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUF C092 BE01 HIEE300910R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg net (Gross: 1.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e38.0 cm x 6.0 cm x 13.0 cm (14.96 in x 2.36 in x 5.12 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Storage: -40 to +70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic side powered via subrack backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eBinary \/ Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e85371092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eDedicated subrack slot insertion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe UF C092 BE01 module connects into the subrack backplane, ensuring high backplane bus communication velocity during real-time scan cycles. Onboard non-volatile memory provides firmware flash compatibility, maintaining persistent channel configuration data and allowing field system updates without board removal. Built-in input filtering circuit logic reduces signal chatter and debounce noise from field contact switches before transferring binary state vectors to the controller backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the UF C092 BE01 binary input module support live insertion during system operation?\u003c\/p\u003e\n\u003cp\u003eA: No. Power to the subrack backplane and field input supply circuits must be disconnected prior to inserting or removing the board to prevent contact arcing and logic bus disruptions.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle high field contact chatter and electrical bounce?\u003c\/p\u003e\n\u003cp\u003eA: Internal hardware RC filtering and digital debounce circuit timing process incoming binary signal transitions, suppressing false status triggers before data is sent across the backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of the front panel retention mechanics?\u003c\/p\u003e\n\u003cp\u003eA: Captive front panel screws secure the module physically into the subrack chassis frame, maintaining continuous backplane multi-pin connector contact and establishing proper chassis grounding path.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize all primary rack backplane power sources and isolate external voltage lines feeding the binary input terminal blocks prior to installation.\u003c\/li\u003e\n\u003cli\u003eAlign the top and bottom edges of the module circuit board with the subrack guide rails.\u003c\/li\u003e\n\u003cli\u003eSlide the unit firmly into the slot until the rear multi-pin edge connector seats completely into the backplane socket.\u003c\/li\u003e\n\u003cli\u003eFasten top and bottom retaining screws to 0.4 Nm to prevent connector loosening due to mechanical vibration.\u003c\/li\u003e\n\u003cli\u003eConnect input wiring using twisted-pair cables, bonding all external wire shielding to the enclosure ground rail to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53224552333621,"sku":"UF C092 BE01 HIEE300910R0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/UFC092BE01HIEE300910R0001.png?v=1785309349","url":"https:\/\/www.5gplc.com\/products\/abb-uf-c092-be01-hiee300910r0001-binary-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}