{"product_id":"abb-ub-c717-ae101-hiee300927r0101-high-voltage-inverter-board","title":"ABB UB C717 AE101 HIEE300927R0101 High Voltage Inverter Board","description":"\u003cp\u003eConfigured for high-voltage DC to AC power conversion in ABB drive systems, the \u003cstrong\u003eABB UB C717 AE101 HIEE300927R0101\u003c\/strong\u003e (\u003cstrong\u003eUBC717AE101\u003c\/strong\u003e High Voltage Inverter Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUB C717 AE101 (HIEE300927R0101)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 cm x 5.1 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 24 VDC control input rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Voltage DC Input\u003c\/td\u003e\n\u003ctd\u003e400 to 800 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 400 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eOver 98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe UB C717 AE101 HIEE300927R0101 inverter board processes switching pulses without disrupting backplane bus communication velocity across control node networks. Hardware-level switching gates convert high-voltage DC input (400 to 800 VDC) to continuous 0 to 400 VAC output with conversion efficiency exceeding 98%. Standardized firmware flash compatibility across connected controller processors ensures deterministic control cycles and supports scalable I\/O density scaling during dynamic load variation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power inputs are required to operate the UB C717 AE101 HIEE300927R0101 inverter board?\u003c\/p\u003e\n\u003cp\u003eA: The board requires a 24 VDC control power supply alongside a primary 400 to 800 VDC input link for high-voltage power conversion.\u003c\/p\u003e\n\u003cp\u003eQ: What protection rating applies to the module assembly housing?\u003c\/p\u003e\n\u003cp\u003eA: The board assembly holds an IP67 protection rating for ingress protection against dust and water immersion.\u003c\/p\u003e\n\u003cp\u003eQ: Can the inverter board be safely serviced or removed while the DC bus is energized?\u003c\/p\u003e\n\u003cp\u003eA: No, all primary 400 to 800 VDC supply feeds and 24 VDC auxiliary control power must be completely isolated and verified discharged before handling the circuit board.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect main 400-800 VDC power supplies and 24 VDC control feeds prior to handling the module.\u003c\/li\u003e\n\u003cli\u003eConfirm zero potential across high-voltage bus capacitor terminals using a calibrated voltmeter.\u003c\/li\u003e\n\u003cli\u003eAttach a grounded ESD wrist strap before touching circuit board edge connections or surface-mount components.\u003c\/li\u003e\n\u003cli\u003eMount the board onto the designated chassis standoff positions and tighten fasteners to secure structural grounding.\u003c\/li\u003e\n\u003cli\u003eInspect power terminal connections to ensure solid contact pressure and prevent high-current electrical arc faults.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53243240448309,"sku":"UB C717 AE101 HIEE300927R0101","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/UBC717AE01_0499aefe-9fc0-4626-9df1-f5377e3b5a5e.png?v=1785745360","url":"https:\/\/www.5gplc.com\/products\/abb-ub-c717-ae101-hiee300927r0101-high-voltage-inverter-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}