{"product_id":"abb-sf810-foc-pyro-tl-flame-scanners","title":"ABB SF810-FOC-PYRO-TL Flame Scanners","description":"\u003cp\u003eThe \u003cstrong\u003eABB SF810-FOC-PYRO-TL\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSF810\u003c\/strong\u003e Flame Scanner, operates as a dedicated hardware component for optical flame signal detection and spectral discrimination within ABB combustion monitoring architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSF810-FOC-PYRO-TL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e175 mm x 138 mm x 257 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC Nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Technology\u003c\/td\u003e\n\u003ctd\u003eOptical Pyrometer \/ Fiber Optic Coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIndustrial Heavy-Duty Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output\u003c\/td\u003e\n\u003ctd\u003eFrequency \/ Analog Flame Intensity Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Integration and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe SF810-FOC-PYRO-TL scanner transmits real-time combustion intensity values to centralized safety shutdown system racks, preserving high backplane bus communication velocity across Profinet and EtherNet\/IP deterministic networks. Signal processing circuits maintain dynamic filtering algorithms to filter background radiation without delaying trip sequence responses. Compact mounting geometry supports maximum cabinet I\/O density scaling during multi-burner field integrations, while modular electronics ensure full firmware flash compatibility across primary burner management system modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the SF810-FOC-PYRO-TL optical head be removed or serviced while the central control loop is active?\u003c\/p\u003e\n\u003cp\u003eA: The sensing electronics may be disconnected, provided the associated burner fuel safety shut-off valve loop is placed in a bypassed or off-line safe state.\u003c\/p\u003e\n\u003cp\u003eQ: How does fiber optic coupling improve signal integrity in harsh combustion environments?\u003c\/p\u003e\n\u003cp\u003eA: Fiber optic conduits isolate the primary optical sensor head from direct thermal conduction, allowing accurate light transmission to the remote processing unit without thermal drift.\u003c\/p\u003e\n\u003cp\u003eQ: What grounding procedure prevents electrical noise interference on the flame intensity signal output?\u003c\/p\u003e\n\u003cp\u003eA: The fiber optic sheath and sensor ground conductor must bond directly to the local panel functional earth point using short, low-impedance copper straps.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that burner power sources and fuel supply lines are isolated prior to mechanical installation.\u003c\/li\u003e\n\u003cli\u003eMount the scanner alignment assembly securely to the sight tube to align the optical axis with the target flame zone.\u003c\/li\u003e\n\u003cli\u003eEnsure fiber optic cables maintain a minimum bend radius of 100 mm to prevent signal attenuation or internal fiber fracture.\u003c\/li\u003e\n\u003cli\u003eTighten cable gland seals to maintain ingress protection against ambient dust, moisture, and combustion air pressure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53253933465909,"sku":"SF810-FOC-PYRO-TL","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/SF810-LOS-IR-TL-CW_ee9e3cf0-ba13-4f9d-a15b-ff70be19166a.png?v=1786006028","url":"https:\/\/www.5gplc.com\/products\/abb-sf810-foc-pyro-tl-flame-scanners","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}