{"product_id":"abb-rem615-hbmcaeagnba1bnn1xg-relion-615-protection-and-control-relay","title":"ABB REM615 HBMCAEAGNBA1BNN1XG Relion 615 Protection and Control Relay","description":"\u003cp\u003eThe \u003cstrong\u003eABB REM615 HBMCAEAGNBA1BNN1XG\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eREM615\u003c\/strong\u003e Motor Protection And Control Relay, operates as a dedicated hardware component for thermal monitoring, fault detection, and circuit switching within Relion 615 series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eREM615 HBMCAEAGNBA1BNN1XG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFinland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Relion 615 series IED enclosure weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact pluggable flush-mount or rack-mount chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow-power internal auxiliary supply draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Capabilities\u003c\/td\u003e\n\u003ctd\u003eThermal overload, start-up\/stall supervision, phase reversal\/unbalance, arc flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850 Ed.1\/Ed.2, Modbus, DNP3, IEC 60870-5-103, Profibus DPV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003ePRP and HSR Ethernet network topologies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Synchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588 v2 time protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003eLarge LCD with single-line diagram, local HMI, web access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Redundancy\u003c\/h3\u003e\n\u003cp\u003eThe REM615 HBMCAEAGNBA1BNN1XG processes current, voltage, and digital feedback inputs via localized hardware buses, optimizing backplane bus communication velocity and logic execution. Designed for high-speed network integration, the relay utilizes IEEE 1588 v2 microsecond time synchronization alongside PRP and HSR Ethernet architectures to maintain deterministic data transmission. Internal firmware flash compatibility supports configuration mapping through PCM600 engineering software, enabling simultaneous reporting over IEC 61850 GOOSE and industrial serial protocols.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Which communication protocols are supported natively for substation automation interfaces?\u003c\/p\u003e\n\u003cp\u003eA: The relay supports IEC 61850 Edition 1 and Edition 2 (including IEC 61850-9-2 LE), Modbus, DNP3, IEC 60870-5-103, and Profibus DPV1 via adapter.\u003c\/p\u003e\n\u003cp\u003eQ: How does the REM615 maintain communication availability during network failures?\u003c\/p\u003e\n\u003cp\u003eA: The device incorporates Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) modes to eliminate network recovery delays upon path disconnection.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms protect against thermal and mechanical stress during motor startup?\u003c\/p\u003e\n\u003cp\u003eA: Integrated thermal overload algorithms, motor start-up counters, load-loss supervision, and locked-rotor stall detection prevent degradation from excessive current draw.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the pluggable REM615 chassis into the panel cutout, ensuring the mechanical frame latch engages securely.\u003c\/li\u003e\n\u003cli\u003eConnect chassis ground to the main switchgear earthing bus using a heavy copper conductor to shield internal electronics from high-frequency noise.\u003c\/li\u003e\n\u003cli\u003eWire current transformer (CT) and voltage transformer (VT) secondary circuits to the rear terminal blocks, verifying correct polarity before applying load.\u003c\/li\u003e\n\u003cli\u003eConnect dual Ethernet cables to the network ports for PRP\/HSR redundancy routing, ensuring minimum bend radius rules are maintained.\u003c\/li\u003e\n\u003cli\u003eApply auxiliary power and verify relay health via the local HMI display and LED status indicators prior to closing primary breaker circuits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53218208055605,"sku":"REM615","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/REM615E_D_cb728afa-e727-4c4a-ba5d-e25674eebe5a.png?v=1785134513","url":"https:\/\/www.5gplc.com\/products\/abb-rem615-hbmcaeagnba1bnn1xg-relion-615-protection-and-control-relay","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}