{"product_id":"abb-pp886-standard-panel-3bse092980r1","title":"ABB PP886 Standard Panel 3BSE092980R1","description":"\u003cp\u003eConfigured for local operator interface manipulation and visualization in ABB automation topologies, the \u003cstrong\u003eABB 3BSE092980R1\u003c\/strong\u003e (\u003cstrong\u003ePP886\u003c\/strong\u003e Operator Panel) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePP886 (Product ID: 3BSE092980R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e410 mm x 286 mm x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +50 deg C (Standard industrial parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (Internal board execution draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen Size\u003c\/td\u003e\n\u003ctd\u003e15.4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Quantity\u003c\/td\u003e\n\u003ctd\u003e1 x Button Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Chemistry\u003c\/td\u003e\n\u003ctd\u003eLithium (Mass: 2.5 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Status\u003c\/td\u003e\n\u003ctd\u003eCompliant with EU Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e2. Screens, Monitors, and Equipment Containing Screens Having a Surface Greater Than 100 cm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe processor framework within the PP886 coordinates field telemetry data routing over integrated communication interfaces. The panel links with external Profinet \/ EtherNet\/IP deterministic networks to manage real-time register updates without degrading system backplane bus communication velocity metrics. Display configuration and data block parsing depend on correct firmware flash compatibility across connected controller platforms. By handling graphics rendering tasks locally through the integrated board processor, the assembly permits expansive I\/O density scaling on the monitored PLC or DCS racks while maintaining sub-second display refresh response windows.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the internal memory profile preserved if primary external power drops?\u003c\/p\u003e\n\u003cp\u003eA: The module contains a single 2.5 g lithium button cell battery. This non-volatile battery block maintains the internal real-time clock configuration and retain-variable registers during complete input power interruption.\u003c\/p\u003e\n\u003cp\u003eQ: Does the panel unit support direct physical substitution while the upstream network controller remains live?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The interface communicates using isolated serial or standard Ethernet nodes. Disconnecting the network line drops local visualization channels but does not interrupt the controller processing loop or backplane data traffic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCutout and Panel Sealing:\u003c\/strong\u003e Mount the 4.15 kg enclosure directly into a rigid cabinet cutout matching the 410 mm x 286 mm structural boundaries. Ensure the perimeter sealing gasket is compressed completely to maintain dust and moisture protection barriers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Continuity Execution:\u003c\/strong\u003e Fasten the frame ground terminal block to the cabinet copper earth bus using a short, low-impedance conductor. Earth routing minimizes high-frequency electrical noise induction across the display matrix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Cable Separation:\u003c\/strong\u003e Route the incoming power feed wires away from high-voltage AC lines and switching drive outputs to eliminate electromagnetic line interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvective Thermal Boundary:\u003c\/strong\u003e Maintain at least 50 mm of unobstructed ventilation space behind the 61 mm depth envelope to ensure proper passive thermal dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53101887586613,"sku":"AFO4LE 1KHL015545R0001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PP886R3BSE092985R1_9b342a94-f814-48b4-916a-2232629f8656.png?v=1783414951","url":"https:\/\/www.5gplc.com\/products\/abb-pp886-standard-panel-3bse092980r1","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}